Address
ASCII: ADDR
The address mark the Sercos station address of the drive, within the Sercos communication The address can
changed between 0 and 63 in the screen "Basic settings".
Address 0 designates the drive as a repeater on the Sercos ring.
Baud Rate
ASCII: SBAUD
In this field it is possible to set the Sercos baud rate.
LWL-Length
ASCII: SLEN
Within this parameter it is possible to change the optical power of the transmit output of the drive, to the next
station in the ring. The optical power can set for the length of plastic optical cable, in meters, from 1 to 45
meters. If the optical power is not adjusted properly, there will be errors in the telegram transmission, and the
red error LED on the drive will light. In normal communication, the green transmit and receive LED's will light
(referring to the LED of the optical transmission).
Phase
ASCII: SPHAS
This field display the actual phase of the Sercos communication.
Status
ASCII: SSTAT
This field displays the actual status of the Sercos communication, according the Sercos status-word in text
format.
With this button you can open the "Sercos Service" screen page.
SERCOS SERVICE
90
07/03
Default: 0
Default: 4MBaud
Default: 5m
Default: -
Default: -
valid for all OPMODES
valid for all OPMODES
valid for all OPMODES
valid for all OPMODES
valid for all OPMODES