Screen page "Drive status"
25
Screen page "Drive status"
Run time
ASCII: TRUN
Display of the operational time of the servo amplifier, saved at 8 minute intervals. If the 24V-supply is switched
off, maximum 8 minutes of operation are unregistered.
Last 10 faults
ASCII: FLTHIST
The last 10 faults that occurred are displayed, together with the time of their occurrence, referred to the
operating hours.
Rate of occurrence
ASCII: FLTCNT
Display of the frequency of all faults that caused the servo amplifier to switch off.
Actual errors
ASCII: ERRCODE
Display of the errors presently being reported by the servo amplifier (corresponds to the error messages Fxx in
the LED-display on the front panel of the amplifier)
Actual warnings
ASCII: STATCODE
Display of the warnings presently being reported by the servo amplifier (corresponds to the
warnings nxx in the LED-display on the front panel of the amplifier)
Reset
ASCII: CLRFAULT
Software-reset of the servo amplifier. The servo amplifier must be disabled.
Present errors are deleted, the firmware is re-initialized, and communication is re-established.
If only errors marked with an asterisk in the error listing are present, then the errors are canceled, but no reset
of the amplifier takes place.
80
07/03
Default: -
Default: -
Default: -
Default: -
Default: -
Default: -
valid for all OPMODES
valid for all OPMODES
valid for all OPMODES
valid for all OPMODES
valid for all OPMODES
valid for all OPMODES