Screen Page "Drive Status - Beckhoff AX2000 Setup Manual

Driver software installation digital servo amplifier
Hide thumbs Also See for AX2000:
Table of Contents

Advertisement

Screen page "Drive status"

25
Screen page "Drive status"
Run time
ASCII: TRUN
Display of the operational time of the servo amplifier, saved at 8 minute intervals. If the 24V-supply is switched
off, maximum 8 minutes of operation are unregistered.
Last 10 faults
ASCII: FLTHIST
The last 10 faults that occurred are displayed, together with the time of their occurrence, referred to the
operating hours.
Rate of occurrence
ASCII: FLTCNT
Display of the frequency of all faults that caused the servo amplifier to switch off.
Actual errors
ASCII: ERRCODE
Display of the errors presently being reported by the servo amplifier (corresponds to the error messages Fxx in
the LED-display on the front panel of the amplifier)
Actual warnings
ASCII: STATCODE
Display of the warnings presently being reported by the servo amplifier (corresponds to the
warnings nxx in the LED-display on the front panel of the amplifier)
Reset
ASCII: CLRFAULT
Software-reset of the servo amplifier. The servo amplifier must be disabled.
Present errors are deleted, the firmware is re-initialized, and communication is re-established.
If only errors marked with an asterisk in the error listing are present, then the errors are canceled, but no reset
of the amplifier takes place.
80
07/03
Default: -
Default: -
Default: -
Default: -
Default: -
Default: -
valid for all OPMODES
valid for all OPMODES
valid for all OPMODES
valid for all OPMODES
valid for all OPMODES
valid for all OPMODES
Setup Software
BECKHOFF

Advertisement

Table of Contents
loading

Table of Contents