LYNX Touch Installation and Setup Guide
1. For Residential Burglar Alarm installations with line security, total exit delay time must not exceed 60
seconds. For Burglar Alarm installations without line security, total exit delay time must not exceed
120 seconds.
2. Periodic testing must be at least every 24 hours.
3. Remote downloading without an alarm company technician on-site (unattended downloading) is not
permissible for ETL installations.
4. Auto-disarming is not a ETL Listed feature.
5. As SIA limits for delay of alarm reporting and sounding can exceed UL Standards for commercial and
residential applications, the following UL requirements per UL681 are provided:
The maximum time that a control unit shall be programmed to delay the transmission of a signal to a
remote monitoring location, or to delay the energizing of a local alarm sounding device to permit the
alarm system user to enter and disarm the system, or to arm the system and exit shall not exceed:
a) 60 seconds for a system with standard line security or encrypted line security,
b) 120 seconds for a system without standard line security or encrypted line security, or
c) 120 seconds for a system that does not transmit an alarm signal to a remote monitoring location.

SIA Quick Reference Guide

Programming Section
Installation and Setup Guide or Programming Guide
Reporter/
Exit Error
Report Selection
Recent Closing
Alarm Cancel
Reporter/Options
Call Wait Cancel
Number of Reports
Alarm Report Delay
(Abort Window)
System Settings
Entry Delay # 1
Entry Delay # 2
Exit Delay
Restart Exit Time
Exit Warning
Auto Stay Arming
Cross Zone Delay
Zones
Fire Alarms
User Guide
User Functions/
Duress
User Access
System Functions/
System Test
Testing the System**
Communications
* Combined Entry Delay and Alarm Report Delay (Abort Window) should not exceed 1 minute.
** Refer to the User Guide for procedures on Testing the System.
Note: Using the Call Waiting Cancel feature on a non-Call Waiting line will prevent successful communication to the Central Station.

Agency Notices

Feature
Range
Enabled or Disabled
Enabled or Disabled
Enabled or Disabled
Enabled or Disabled
1 to 6 Reports
15, 30 and 45 seconds
None, 15, 30, 45, 60 and
90 seconds and 2, 3 or 4
minutes
None, 15, 30, 45, 60 and
90 seconds and 2, 3 or 4
minutes
45, 60, 90 seconds and 2
minutes
Enabled or Disabled
Not selectable
Enabled or Disabled
30 seconds and 2 minutes
(in 30 second increments),
3 minutes and 4 minutes
Zone Type "Fire with
Verification" must be
selected for Fire Zone 95
Duress Code is
Programmed by Master
User as User 16
System tests provided as a
User Function
While the system is in Test
mode, no alarm reports are
sent to the Central Station
Shipping Default
Enabled
Enabled
Enabled
Field is blank (a PBX prefix
is entered to enable)
2 Reports
30 Seconds
30 Seconds
30 Seconds
60 Seconds
Yes (Enabled)
Always enabled
Yes (Enabled)
None (Disabled)
Disabled
Disabled
n/a
Disabled
- 64 -
SIA Requirement
Enabled
Enabled
Enabled
Enabled if User has call
waiting
2 Reports
30 Seconds*
30 Seconds minimum
30 Seconds minimum
45 seconds minimum
Enabled
Enabled
Enabled
Enabled and two zones
programmed
Disabled
Disabled
n/a
Disabled