SEC PHONE.

Scroll to the "Sec Phone" option to enter the central station secondary phone number in the
system. Valid entries for the entering the secondary phone number are 0–9, # + 11 for '∗', # +
12 for '#', # + 13 for a pause (2 seconds).
Note: When stepping through the Phone Number and Sub ID (subscriber ID and Central
station phone number fields), the existing data is displayed. If the field is selected for
editing, the data in that field will be deleted. The field can be left blank by pressing the ADD
key. Enter new data and then press the ADD key.

Add Secondary Phone Number

SEC SUB ID

Scroll to the "Sec Sub Id " option to enter the central station secondary subscriber ID account
number in the system.
Note: When stepping through the Phone Number and Sub ID (subscriber ID and Central
station phone number fields), the existing data is displayed. If the field is selected for
editing, the data in that field will be deleted. The field can be left blank by pressing the ADD
key. Enter new data and then press the ADD key.

Add Secondary Sub ID Account Number

ADD SENSORS.

Scroll to the "Add Sensors" option to enroll RF sensors in the system.

Add A Door Sensor

Doors added have Zone Type 01, exit/entry operation.
"Add Sensors"
www.PDF-Zoo.com
Enter first
central station
Scroll to
phone number
(up to 20 digits)
"Pri. Phone"
Press
Press
[SELECT]
[ADD]
All four digits of the Central Station Account number must be entered.
!
is being used, all ten digits must be entered.
Enter second
central station
account number
Scroll to
(up to 4 or 10 digits)
"Sec. Sub ID"
Press
Press
[ADD]
[SELECT]
The LXL-1010 will enroll a sensor once the transmitter has been activated twice. LXL-
!
1010 confirms the enrollment following subsequent activation of the same transmitter.
Scroll to
Scroll to
"Add Door Sensor"
Press
Press
[SELECT]
[SELECT]
firealarmresources.com
Section 2: Quick Start Installation Guide
Scroll to next
option or ESC
Scroll to next
option or ESC
Scroll to
sensor location
Press
Scroll
to
[SELECT]
Sensor location
If ten-digit format
Activate
transmitter
Press
twice. To enter
[SELECT]
S/N manually
Press (SELECT)
Scroll to next
option or ESC
Press
[ADD]
2–5

Advertisement

Table of Contents
loading

This manual is also suitable for:

Lxl-1010

Table of Contents