Basler DGC-2020 Instruction Manual page 245

Digital genset controller
Table of Contents

Advertisement

Holding
Parameter
Register
1 Phase Loss of Excitation
44422
Hysteresis
44424-498
FUTURE USE
ALARMS
44500
High Coolant Temp Alarm Enable
High Coolant Temp Alarm
44502
Threshold
Metric High Coolant Temp Alarm
44504
Threshold
High Coolant Temp Alarm
44506
Activation Delay
44508
Low Oil Press. Alarm Enable
44510
Low Oil Press. Alarm Threshold
Metric Low Oil Press. Alarm
44512
Threshold
44514
Low Oil Press. Alarm Arming Delay
44516
Overspeed Alarm Enable
44518
Overspeed Alarm Threshold
44520
Overspeed Alarm Activation Delay
44522
Low Fuel Level Alarm Enable
44524
Low Fuel Level Alarm Threshold
Low Fuel Level Alarm Activation
44526
Delay
High Coolant Temp Pre-Alarm
44528
Enable
High Coolant Temp Pre-Alarm
44530
Threshold
Metric High Coolant Temp Pre-
44532
Alarm Threshold
Low Coolant Temp Pre-Alarm
44534
Enable
Low Coolant Temp Pre-Alarm
44536
Threshold
Metric Low Coolant Temp Pre-
44538
Alarm Threshold
High Fuel Level Pre-Alarm
44540
Threshold
44542
High Fuel Level Pre-Alarm Enable
High Fuel Level Pre-Alarm
44544
Activation Delay
44546
Low Fuel Level Pre-Alarm Enable
Low Fuel Level Pre-Alarm
44548
Threshold
44550
Low Battery Pre-Alarm Enable
44552
Low Battery Pre-Alarm Threshold
Low Battery Pre-Alarm Activation
44554
Delay
44556
Weak Battery Pre-Alarm Enable
44558
Weak Battery Pre-Alarm Threshold
Weak Battery Pre-Alarm Activation
44560
Delay
Battery Overvoltage Pre-Alarm
44562
Enable
9400200990 Rev I
Range
10-100
0-1
100-280
37-137
50-150
0-1
3-150
25-1030
5-15
0-1
105-140
0-500
0-1
0-100
0-30
0-1
100-280
37-137
0-1
32-150
10-37
0-100
0-1
0-30
0-1
10-100
0-1
120-240 for 24V
60-120 for 12V
1-10
0-1
80-160 for 24 V
40-80 for 12V
1-10
0-1
DGC-2020 Modbus™ Communication
Read/Write
Data
Supported
Format
R W
Deci-percent in increments of 1
0 = Disable
R W
1 = Enable
R W
°F in increments of 1
R W
°C in increments of 1
RW
Seconds in increments of 1
0 = Disable
R W
1 = Enable
R W
psi in increments of 1
R W
kPa in increments of 1
R W
Seconds in increments of 1
0 = Disable
R W
1 = Enable
R W
% in increments of 1
R W
Milliseconds in increments of 1
0 = Disable
R W
1 = Enable
R W
% in increments of 1
R W
Seconds in increments of 1
0 = Disable
R W
1 = Enable
R W
°F in increments of 1
R W
°C in increments of 1
0 = Disable
R W
1 = Enable
R W
°F in increments of 1
R W
°C in increments of 1
R W
% in increments of 1
0 = Disable
R W
1 = Enable
R W
Seconds In increments of 1
0 = Disable
R W
1 = Enable
R W
% in increments of 1
0 = Disable
R W
1 = Enable
R W
(Volts DC / 10) in increments of 1
R W
Seconds in increments of 1
0 = Disable
R W
1 = Enable
R W
(Volts DC / 10) in increments of 1
R W
Seconds in increments of 1
0 = Disable
R W
1 = Enable
Units
B-29

Advertisement

Table of Contents
loading

Table of Contents