Basler DGC-2020 Instruction Manual page 155

Digital genset controller
Table of Contents

Advertisement

Terminal
8 (OIL)
9 (FUEL)
10 (COOLANT)
11 (SENDER COM)
Magnetic Pickup Input
The magnetic pickup input accepts a speed signal over the range of 3 to 35 volts, peak and 32 to 10,000
hertz. Magnetic pickup input terminals are listed in Table 6-6.
Terminal
31 (MPU+)
32 (MPU–)
Contact Sensing Inputs
Contact sensing inputs consist of 1 emergency stop input and 16 programmable inputs.
The emergency stop input is intended for use with a normally closed switch and recognizes an
emergency stop input when the short-circuit across the input is removed.
The programmable inputs accept normally open, dry contacts. Terminal 2 (BATT–) serves as the common
return line for the programmable inputs. Information about configuring the programmable inputs is
provided in Section 4, BESTCOMSPlus Software.
Contact sensing input terminals are listed in Table 6-7.
Terminal
2 (BATT–)
15 (INPUT 16)
16 (INPUT 15)
17 (INPUT 14)
18 (INPUT 13)
19 (INPUT 12)
20 (INPUT 11)
21 (INPUT 10)
22 (INPUT 9)
23 (INPUT 8)
24 (INPUT 7)
25 (INPUT 6)
26 (INPUT 5)
27 (INPUT 4)
28 (INPUT 3)
29 (INPUT 2)
30 (INPUT 1)
46 (ESTOP)
47 (ESTOP)
9400200990 Rev I
Table 6-5. Sender Input Terminals
Oil pressure sender input
Fuel level sender input
Coolant temperature sender input
Sender return terminal
Table 6-6. Magnetic Pickup Input Terminals
Description
Magnetic pickup positive input
Magnetic pickup return input
Table 6-7. Contact Sensing Inputs
Common return line for programmable contact inputs
Programmable contact input 16
Programmable contact input 15
Programmable contact input 14
Programmable contact input 13
Programmable contact input 12
Programmable contact input 11
Programmable contact input 10
Programmable contact input 9
Programmable contact input 8
Programmable contact input 7
Programmable contact input 6
Programmable contact input 5
Programmable contact input 4
Programmable contact input 3
Programmable contact input 2
Programmable contact input 1
Emergency stop contact input
DGC-2020 Installation
Description
Description
6-5

Advertisement