Bookstyle and Compact, Mains supply
3 x 380 - 500 V
According to international requirements
Output current
Output
Typical shaft output
Typical shaft output
Max. cable cross-section to motor,
brake and loadsharing [mm
Rated input current
Max. cable cross-section power [mm
Max. pre-fuses [-]/UL
Efficiency
Weight IP 20 EB Bookstyle [kg]
Weight IP 20 EB Compact [kg]
Weight IP 54 EB Compact [kg]
Power loss at max.
load.
Enclosure
1. For type of fuse see section Fuses.
2. American Wire Gauge.
3. Measured using 30 m screened motor cables at rated load and rated frequency.
MG.51.A9.02 - VLT is a registered Danfoss trademark
I
VLT, MAX
I
VLT, MAX
S
VLT,N
S
VLT,N
2
2
]/[AWG]
)
2
]/[AWG]
1)
[A]
3)
®
VLT
VLT type
5005
I
[A] (380-440 V)
7.2
VLT,N
(60 s) [A] (380-440 V)
11.5
I
[A] (441-500 V)
6.3
VLT,N
(60 s) [A] (441-500 V)
10.1
[kVA] (380-440 V)
5.5
[kVA] (441-500 V)
5.5
P
[kW]
3.0
VLT,N
P
[HP]
4
VLT,N
4/10
I
[A] (380 V)
7
L,N
I
[A] (460 V)
6
L,N
2)
4/10
16/15
0.96
7.5
8.5
12
[W]
139
IP 20/
IP 54
5000 Series
5006
5008
5011
10
13
16
16
20.8
25.6
8.2
11
14.5
13.1
17.6
23.2
7.6
9.9
12.2
7.1
9.5
12.6
4.0
5.5
7.5
5
7.5
10
4/10
4/10
4/10
9.1
12.2
15.0
8.3
10.6
14.0
4/10
4/10
4/10
25/20
25/25
35/30
0.96
0.96
0.96
9.5
9.5
9.5
10.5
10.5
10.5
14
14
14
198
250
295
IP 20/
IP 20/
IP 20/
IP 54
IP 54
IP 54