6 Operation
46
6.2
HOME Position
After turning on the power, LCD shows the current data on HOME position.
Figure. 50: HOME Position
The letters A, B, C and D stand for the areas where information on measured values and status of the device
are displayed:
Area
A
B
C
D
The meanings of message appearing on LCD (display) is explained in the following table.
Gauge Status
G - RE
Reference position for measuring
UP
The measuring wire is hoisted.
STOP
The measuring wire stops.
LIQU
The liquid is being measured.
U - IF
The upper interface level is being measured.
LIF
The lower interface level is being measured.
BOTM
The tank bottom level is being measured.
U - DE
The upper liquid density is being measured.
M - DE
The middle liquid density is being measured.
B - DE
The bottom liquid density is being measured.
CAN
Resetting RELE.OVER TENS (over tension error).
TEAC
Calibration is being measured.
blank
Measuring is not possible.
Information
Current Level
Current Temperature
Gauge Status
Displacer Status
Description
Proservo NMS5
Endress+Hauser
Need help?
Do you have a question about the Proservo NMS5 and is the answer not in the manual?