82 Guidelines for planning the electrical installation

Additional requirements for non-ABB high-output and IP23 motors

The rated output power of high-output motors is higher than what is stated for the
particular frame size in EN 50347 (2001).
If you plan to use a non-ABB high-output motor or an IP23 motor, consider these additional
requirements for protecting the motor insulation and bearings in drive systems:
If motor power is below 350 kW: Equip the drive and/or motor with the filters and/or
bearings according to the table below.
If motor power is above 350 kW: Consult the motor manufacturer.
Nominal AC line
voltage
Motor insulation
U
< 420 V
Standard: Û
N
1300 V
420 V < U
< 500 V Standard: Û
N
1300 V
or
Reinforced: Û
1600 V, 0.2
microsecond rise
time
500 V < U
< 600 V Reinforced: Û
N
1600 V
or
Reinforced: Û
1800 V
600 V < U
< 690 V Reinforced: Û
N
1800 V
Reinforced: Û
2000 V, 0.3
microsecond rise
time ***
***
If the intermediate DC circuit voltage of the drive is increased from the nominal level due to long term
resistor braking cycles, check with the motor manufacturer if additional output filters are needed in the
applied drive operation range.
ABB du/dt and common mode filters, insulated N-end motor
system
P
< 100 kW or frame
N
size < IEC 315
P
< 134 hp or frame
N
size < NEMA 500
=
+ N or CMF
LL
=
+ du/dt + (N or CMF)
LL
=
+ N or CMF
LL
=
+ du/dt + (N or CMF)
LL
=
+ N or CMF
LL
=
+ N + du/dt
LL
=
+ N + CMF
LL
Requirement for
bearings
100 kW < P
IEC 315 < frame size < IEC 400
134 hp < P
NEMA 500 < frame size < NEMA 580
+ N + CMF
+ N + du/dt + CMF
+ N + CMF
+ N + du/dt + CMF
+ N + CMF
+ N + du/dt + CMF
+ N + CMF
< 350 kW or
N
< 469 hp or
N

Advertisement