REV A
6 Continue at full speed and note the time when
the machine reference point crosses the finish
line.
7 Press down the foot switch and lower the boom
to the stowed position.
8 Extend the boom 1 foot / 30 cm.
9 Choose a point on the machine; i.e., contact
patch of a tire, as a visual reference for use
when crossing the start and finish lines.
10 Bring the machine to top drive speed before
reaching the start line. Begin timing when your
reference point on the machine crosses the
start line.
11 Continue at top speed and note the time when
the machine reference point crosses the finish
line. Refer to Section 2, Specifications.
Part No. 75861
Section 3 • Scheduled Maintenance Procedures
B-19
Test the Alarm Package
(if equipped)
The alarm package includes:
· Travel alarm
· Descent alarm
· Flashing beacons
Alarms and beacons are installed to alert operators
and ground personnel of machine proximity and
motion. The alarm package is installed on the
turntable rear cover. Beacons are installed on both
turntable covers.
1 Turn the key switch to ground controls and pull
out the red Emergency Stop button to the on
position at both the ground and platform
controls.
Result: Both flashing beacons should be on and
flashing.
2 Hold the function enable switch to either side
and activate the boom toggle switch in the down
position, hold for a moment and then release it.
Result: The descent alarm should sound when
the toggle switch is held down.
Genie Z-60/34
CHECKLIST B PROCEDURES
The alarms and beacons will
operate with the engine
running or not running.
3 - 31