Test The Fuel Select Operation - Ford Models - Genie Z-60/34 Service Manual

Hide thumbs Also See for Z-60/34:
Table of Contents

Advertisement

Section 3 • Scheduled Maintenance Procedures
CHECKLIST B PROCEDURES
B-15
Test the Fuel Select Operation -
Ford Models
The ability to select and switch between
gasoline and LPG fuels as needed is essential to
safe machine operation. A fuel selection can be
made when the engine is running or not.
Switching malfunctions and/or the failure of the
engine to start and run properly in both fuel
modes and through all idle speeds can indicate fuel
system problems that could develop into a
hazardous situation.
Perform this test after checking
the gasoline and LPG fuel levels,
and warming the engine to normal
operating temperature.
1 At the platform controls, move the fuel select
switch to gasoline and then move the engine
idle control switch to foot switch activated high
idle (rabbit and foot switch symbol).
2 Start the engine from the platform controls and
allow it to run at low idle.
3 - 28
3 Press down the foot switch to allow the engine
to run at high idle.
Result: The engine should start promptly and
operate smoothly in low and high idle.
4 Release the foot switch and shut the engine off
by pushing in the red Emergency Stop button in
to the off position.
5 Move the fuel select switch to LPG.
6 Restart the engine and allow it to run at
low idle.
7 Press down the foot switch to allow the engine
to run at high idle.
Result: The engine should start promptly and
operate smoothly in low and high idle.
Genie Z-60/34
November 2003
The engine may hesitate
momentarily and then continue
to run on the selected fuel if the
fuel source is switched while
the engine is running.
Part No. 75861
REV A