Bennett Marine AutoTrimPro Installation & User Manual page 9

All-in-one trim tab control system, hydraulic trim tab systems
Table of Contents

Advertisement

Installation of System Components
continued
green sensor wire on the ATP
Control Unit. (Use the provided
adapter if needed).
Testing the system
1. Reconnect the battery(s) or turn
the battery switch to ON.
2. Turn the ignition to the ON
position.
3. The ATP Helm Display should
illuminate, and all red tab position
LEDs should be flashing. This
indicates that the system needs
to be calibrated. If sensors are
properly installed (See page 6),
detection of the sensors will be
indicated by the upper yellow
LEDs on the Helm Control
continuously illuminated. Also the
2 green LEDs on the Control Unit
will be continuously illuminated.
4. The two blue LEDs over FAV1
and FAV2 should be flashing. This
is an indication that the system
has not yet been oriented to the
boat (You will complete this step
on page 23).
Bennett Marine AutoTrim Pro | Need help? Call (954) 427-1400
5. Press the PORT Bow DN button
on the ATP Helm Display. The
starboard actuator should extend.
If the starboard actuator does not
extend, or the port actuator
extends instead of the starboard
actuator, refer to the
troubleshooting section on
page 44.
6. Press the STBD Bow DN button
on the ATP Helm Display. The
port actuator should extend. If
the port actuator does not extend,
or the starboard actuator extends
instead of the port actuator, refer
to the troubleshooting section on
page 44.