System Set Up:
This step should be completed before the boat is launched
Actuator Position Calibration With Sensors
See page 22 for set-up if sensors are NOT present. See page 6 to learn about
the purpose of sensors and to determine if you currently have sensors or not.
The red tab position LEDs on the Helm Display should be flashing alternately
PORT and STBD. This is the system's indication that there is no actuator
calibration stored yet.
1.
If the upper yellow LEDs are
flashing, the system does not
detect the presence of sensors in
the actuators. Check to make sure
the red and green sensor cables are
connected to the ATP Control
Unit. If the system does not have
actuator sensors, skip to page 22.
2.
Press and hold the bright (Sun)
and dim (Moon) buttons
simultaneously for about three
20
Bennett Marine AutoTrim Pro | Need help? Call (954) 427-1400

Actuator Position Calibration

seconds. This will enter the
system into calibration mode.
The lower two yellow LEDs
should begin to flash.
3. Press and hold both Bow DN
buttons until both actuators are
fully extended.
4. After a few seconds, the upper two
yellow LEDs should begin to flash.