9.2.2
ME-ARC Remote's ACLD-specifi c TECH Menus
Press the ME-ARC's TECH button, and rotate the SELECT knob to access:
TECH: 01 Temperature (rotate SELECT knob until ACLD Temp displays)
ACLD Temp – Displays the temperature of the ACLD load diversion controller plugged into
the NETWORK port on the inverter (taken from the METER: 06C ACLD Temp display).
TECH: 02 Versions (rotate SELECT knob until AGS displays)
ACLD: #.# – Displays the software version of the ACLD connected to the Magnum network
(displays "0.0" if the remote does not sense an ACLD).
9.2.3

ACLD Menu Maps

The diagram below is a complete overview of the ACLD information displays available from the
ME-ARC remote's METER button ACLD menu.
METER
[Status/Fault]
06 ACLD Meters
P
06A ACLD Status
[Status/Fault]
Available Statuses:
Active – Absorb
Active – Bulk
Active – Float
Desat Fault
High Current Fault
Press button
Press SELECT
© 2014 Magnum Energy, Inc.
Read Only displays
06B ACLD Power
R
Diverted: 1.7 KW
06E ACLD-40
Version:
High VAC In Fault
Inactive
No Comm (No ACLD present) Standby – Absorb
No Load Fault
Output Short Fault
LEGEND
Menu Button
METER
[Status/Fault]
06 ACLD Meters
P
06A ACLD Status
[Status/Fault]
R = rotate SELECT knob

Figure 9-1, ACLD METER Menu Map

Using an ACLD: Monitoring
06C ACLD Temp
R
32F
06D Target Volts
R
1.0
0.0 VDC /
Overcurrent Fault
Overtemp Fault
Standby – Bulk
Standby – Float
Inverter/Charger Status
Menu Item
Menu Selection
ACLD Status/Meter
R
77F
Page 96