Magnum Energy ME-ARC50 Owner's Manual page 136

Me-arc series. advanced remote control. version 4.0 or higher: with ags, bmk, acld, and pt info
Hide thumbs Also See for ME-ARC50:
Table of Contents

Advertisement

Appendix A – ME-ARC Compatibility Matrix
Menu
Main
Menu
Heading/Item
04D Gen Run SOC
04E Gen Run Temp
04F Max Gen Run
Time
04G Quiet Time
04
AGS
Setup
04H Gen Exercise
04I Gen Warm-up
Time
04J Gen Cooldown
Time
04K Gen 100% SOC
Start Days
05
05A Charge Eff
BMK
Setup
05B AmpHour Size
06
06A Battery Type
PT
Setup
Page 129
Features/Settings
Selections/
Adjustments Range
OFF, Start Gen SOC = 20-99%
Stop Gen SOC = 21-100%
Start = OFF, Ext Input, 65-95F
(18-35C)
Run Time = 0.5-25.5 Hrs
OFF, 0.1-25.5 Hrs
OFF, ON–Start = 12:00A - 11:45P
Stop Quiet Time = 12:00A - 11:45P
Quiet Time Topoff = OFF, 30-120 Min
Days = OFF, 1-255 days
Run Hour/Min/AM-PM = 12:00A -
11:45P
Run Time = 0.1-25.5 Hrs
0-127 sec, 1-127 min
0-127 sec, 1-127 min
OFF, 1-255 Days
SOC Hour/Minute/AM-PM =
12:00A - 11:45P
Auto, 50-99%
200-2500 AH
Gel, Flooded, AGM1, AGM2
Max Charge = OFF, 20-990A
CV Charge = 12.0-16.6* VDC
CV Chg Done = Time, Amps,
CC/
Hold CV Chg VDC
CV
Time = 0.1-25.5
Max CC/CV Time = OFF,
0.1-25.5 Hrs
Recharge = 9.0-16.0* Volts
Absorb (12.0-16.6)*
Float (12.0-16.6)*
EQ (12.0-16.6)*
EQ Done (0.1-25.5)
Model/
Level
Default
Required
OFF
≥Level 1
[6]
90%
OFF
≥Level 1
2.0 Hrs
≥Level 1
12.0 Hrs
OFF
≥Level 1
OFF
OFF
≥Level 1
1.0 Hrs
≥Level 1
60 Sec
≥Level 1
60 Sec
OFF
≥Level 4
[5]
≥Level 1
Auto
[6]
≥Level 1
400 AH
[6]
≥Level 1
Flooded
200 ADC
13.8*
Time
≥Level 1
2.0 Hrs
12.0 Hrs
12.0*
14.4*
13.2*
≥Level 1
15.6*
4.0 Hrs