Firmware Update; Video Panel Firmware Update - Chauvet DJ Vivid Drive 23N User Manual

Hide thumbs Also See for Vivid Drive 23N:
Table of Contents

Advertisement

Operation

Firmware Update

To update the firmware of the Vivid Drive 23N, follow the instructions below.
1.
On a Windows PC, download the latest firmware update from
drive-23n/.
2.
Plug the product into power, connect it to the computer, and open NovaLCTMars.
3.
Click User (U) in the menu running across the top of the window to open the drop-down menu.
4.
Click Advanced User Login (A).
5.
Type admin into the password field, and press the Login button on the screen, or press the Enter
key.
6.
Type admin again (There won't be a field for this, just type anywhere in the window). The
Program Loading window will pop up.
7.
If more than one Vivid Drive 23N is connected, select the one to be updated from the Current
Operation Communication Port drop-down menu.
8.
Click the button to the right of Program Path, and browse to find and select the firmware update
file.
9.
Select the Sending Card check-box.
10. Click Update.
11. On the Vivid Drive 23N, access the
12. Use the <SELECT> knob to select USB UPGRADE.
13. Press the <SELECT> knob.
14. Press the <SELECT> knob to confirm, or press <MENU> to cancel.

Video Panel Firmware Update

To update the firmware for a video panel connected to the Vivid Drive 23N, do the following:
1.
Download the latest firmware update from the manufacturer website. For example, the latest
firmware update for the Vivid 4 from CHAUVET DJ can be downloaded from www.chauvetdj.com.
2.
Plug the video panel and Vivid Drive 23N into power, connect the products together and to the
computer, and open NovaLCTMars.
3.
Click User (U) in the menu running across the top of the window to open the drop-down menu.
4.
Click Advanced User Login (A).
5.
Type admin into the password field, and press the Login button on the screen, or press the Enter
key.
6.
Type admin again (There won't be a field for this, just type anywhere in the window). The
Program Loading window will pop up.
7.
If more than one Vivid Drive 23N is connected, select the one connected to the panel to be
updated from the Current Operation Communication Port drop-down menu.
8.
Click the button to the right of Program Path, and browse to find and select the firmware update
file.
9.
Select the Receiving Card FPGA check-box.
10. Click Update.
Vivid Drive 23N User Manual Rev. 1
SYSTEM
Settings.
www.chauvetdj.com/products/vivid-
Page 26 of 31