19.
20.
21.
22.
Replacing SAS cables connected to a CBLM or CBLH
controller
Replacing SAS cables for a CBLM or CBLH controller requires you to block a
back end module before replacing the cables.
Procedure
1.
240
• When replacing DW-F800-SCQ1HA cables, pull the cable latches to
remove the cables from the SAS adapters. Attach new cables to the
SAS adapters and connect to the ENC.
• When replacing the SAS adapter of the SAS cable (DW-F800-
SCQ1HA), install the cable to a new SAS adapter, and then connect it
to the ENC and route the cable.
Note: The SAS cable does not have to be routed when connecting
the DW-F800-SCQ1HA SAS adapter.
At the Replace Controller Board window, click Restore.
A progress bar shows the replacement status.
Note: The restore operation can take up to 20 minutes to
complete. If a message states that the recovery failed, go to the
Customer Contact Us page at
contact-us.html.
When the progress bar goes away and the completion message appears,
click Close.
Click the CTLs tab, and then check that the controller whose SAS cable
you replaced is Normal.
Log out and close the Maintenance Utility window.
Start the maintenance utility.