Checking the power supply
Procedure
1.
2.
3.
4.
5.
Replacing a power supply for a CBSS or CBSL
Caution: Be sure to replace the faulty power supply. If you replace the
operational power supply, the system will go down.
Caution: A short-circuit can cause a fire. Never insert metal or other objects
into the cable connector; otherwise, a short-circuit can occur.
Note: Power supply unit #1 and power supply unit #2 are installed in
opposite directions.
142
Start the maintenance utility.
Click Hardware > Controller Chassis, Hardware > Drive Box or
Hardware > Channel Board Box.
Click the PSs tab.
To display the most recent status of the power supply, click Refresh.
Confirm that the status of the power supply to be replaced is Warning.
Replacing a power supply
Service Guide for VSP Gx00 and VSP Fx00 Models