Checking the SFP

Before you begin
Confirm that the red PORT LED is on at the front end module whose SFP will
be replaced.
Procedure
1.
2.
3.
4.
5.
6.

Replacing an SFP on a controller

Install the same type of SFP as the one being replaced. The color of the lever
or the entire SFP identifies the SFP type:
• Shortwave SFPs are black.
• Longwave SFPs are blue.
214
Start the maintenance utility.
In the Maintenance Utility window, click Hardware > Controller
Chassis or Hardware > Channel Board Box.
Click the CHBs tab.
Confirm that the status of the SFP to be replaced is Warning.
In the SFP Status column, click the warning to display a pop-up window
with SFP port ID, status, and type information.
Replace the SFP. Do not click Close at this time.
Replacing a small form-factor pluggable (SFP)