Hitachi g600 Reference Manual

Hitachi g600 Reference Manual

Virtual storage platform
Hide thumbs Also See for g600:
Table of Contents

Advertisement

Hitachi Virtual Storage Platform
G400,
G600
Hardware Reference Guide
MK-94HM8022-05
June 2016

Advertisement

Table of Contents
loading

Summary of Contents for Hitachi g600

  • Page 1 Hitachi Virtual Storage Platform G400, G600 Hardware Reference Guide MK-94HM8022-05 June 2016...
  • Page 2 Materials. “Materials” mean text, data, photographs, graphics, audio, video and documents. Hitachi reserves the right to make changes to this Material at any time without notice and assumes no responsibility for its use. The Materials contain the most current information available at the time of publication.
  • Page 3: Table Of Contents

    Hitachi Virtual Storage Platform G600 model............20 Features........................ 22 Scalability......................22 Examples of supported Hitachi Virtual Storage Platform G400 configurations..22 Examples of supported Hitachi Virtual Storage Platform G600 configurations..22 Maximum number of mounted drive trays............23 Hitachi Virtual Storage Platform G400, G600 Hardware Reference Guide...
  • Page 4 Using flash module drives..................80 Powering off the storage system................81 Removing cables....................81 5 User administration for maintenance utility........83 Required roles for operating Maintenance Utility............84 Setting up user accounts..................85 Hitachi Virtual Storage Platform G400, G600 Hardware Reference Guide...
  • Page 5 VSP G400 and VSP G600 mechanical specifications..........104 Electrical specifications..................109 Environmental specifications................. 110 Battery specifications....................113 RAID specifications....................113 iSCSI specifications....................114 iSCSI standards....................117 Regulatory compliance..................117 Dense intermix drive tray connection restrictions............ 118 SVP hardware specifications.................. 118 Index....................121 Hitachi Virtual Storage Platform G400, G600 Hardware Reference Guide...
  • Page 6 Hitachi Virtual Storage Platform G400, G600 Hardware Reference Guide...
  • Page 7: Preface

    □ Product version □ Release notes □ Changes in this revision □ Document conventions □ Conventions for storage capacity values □ Accessing product documentation □ Getting help □ Comments □ Preface Hitachi Virtual Storage Platform G400, G600 Hardware Reference Guide...
  • Page 8: Safety And Environmental Notices

    Backup Hitachi cannot guarantee against data loss due to failures. Therefore, back up your data to minimize chances for data loss. Data backup is also critical when hardware components are added or replaced, because performing such hardware procedures restores parameter settings that can affect how data is managed on the storage systems.
  • Page 9: General Safety Guidelines

    DAMAGE. Notes on use When using the Hitachi storage system, be sure to read this guide and understand the operating procedures and instructions described herein thoroughly before staring your operation. The array complies with FDA radiation performance standard 21 CFR subchapter J.
  • Page 10: Handling Of Heavy Parts

    • Do not supply power to any device with rotating or moving parts that are not properly covered. • Tuck in your tie, scarf, shirt, or any other loose clothing to prevent it from getting caught by a rotating or moving part. Preface Hitachi Virtual Storage Platform G400, G600 Hardware Reference Guide...
  • Page 11: Preventing Machine Damage

    • Keep these vents open and be sure they are not blocked to keep the storage system ventilated. Cool air enters the storage system from the air vent on the front panel and exits through the vent on the rear panel. Preface Hitachi Virtual Storage Platform G400, G600 Hardware Reference Guide...
  • Page 12: Procedures In An Emergency

    • If the fire continues to burn after the power is shut off, take suitable actions, including the use of a fire extinguisher, or call the fire department. Intended audience This document is intended for system administrators, Hitachi Data Systems representatives, and authorized service providers who install, configure, or operate VSP Gx00 models .
  • Page 13: Product Version

    (For exceptions to this convention for variables, see the entry for angle brackets.) Indicates text that is displayed on screen or entered by the user. Example: Monospace pairdisplay -g oradb < > angle brackets Indicates variables in the following scenarios: Preface Hitachi Virtual Storage Platform G400, G600 Hardware Reference Guide...
  • Page 14: Conventions For Storage Capacity Values

    1 petabyte (PB) 1,000 TB or 1,000 bytes 1 exabyte (EB) 1,000 PB or 1,000 bytes Logical storage capacity values (for example, logical device capacity) are calculated based on the following values: Preface Hitachi Virtual Storage Platform G400, G600 Hardware Reference Guide...
  • Page 15: Accessing Product Documentation

    Getting help Hitachi Data Systems Support Connect is the destination for technical support of products and solutions sold by Hitachi Data Systems. To contact technical support, log on to Hitachi Data Systems Support Connect for contact information: https://support.hds.com/en_us/contact-us.html. Hitachi Data Systems Community...
  • Page 16 Preface Hitachi Virtual Storage Platform G400, G600 Hardware Reference Guide...
  • Page 17: Product Overview

    The storage system allows a defective controller to be replaced. The Virtual Storage Platform G400, G600 can be equipped with NAS modules. The NAS modules provide file access through CIFS, NFS and FTP protocols and block access using iSCSI protocols in addition to the block access provided directly by iSCSI and FC I/O modules.
  • Page 18 Features □ Scalability □ Product overview Hitachi Virtual Storage Platform G400, G600 Hardware Reference Guide...
  • Page 19: Block Configuration

    • Maximum number of drives supported: 384 (480 with dense intermix drive tray) • Maximum cache memory supported: 128 GB (64 GB per controller) Controller Controller chassis Controller model Height CBLM DW800-CBL DW-F800-CTLM 4U (174.3 mm) Product overview Hitachi Virtual Storage Platform G400, G600 Hardware Reference Guide...
  • Page 20: Hitachi Virtual Storage Platform G600 Model

    • 8 GB Fibre Channel: 56 ports per system (or 64 ports per systems for systems with no drives). • 16 GB Fibre Channel: 28 ports per system (or 32 ports per systems for systems with no drives). Product overview Hitachi Virtual Storage Platform G400, G600 Hardware Reference Guide...
  • Page 21 3.5-inch LFF 4U (174.3 mm) DB60 (power drive tray supply, contains BNST) • DW-F800- DB60C Related references • Examples of supported Hitachi Virtual Storage Platform G600 configurations on page 22 Product overview Hitachi Virtual Storage Platform G400, G600 Hardware Reference Guide...
  • Page 22: Features

    SFF drive tray 576 HDDs or SSDs LFF drive tray 288 HDDs or SSDs FMD drive tray 288 HAF flash module drives Dense intermix drive tray 720 HDDs or SSDs Product overview Hitachi Virtual Storage Platform G400, G600 Hardware Reference Guide...
  • Page 23: Maximum Number Of Mounted Drive Trays

    Maximum number of mounted drives for VSP (up to 12 per path) G400 Dense intermix drive SFF drive + dense LFF drive + dense SFF, LFF drives tray intermix drive tray intermix drive tray Product overview Hitachi Virtual Storage Platform G400, G600 Hardware Reference Guide...
  • Page 24 SFF drive + dense LFF drive + dense SFF, LFF drives tray intermix drive tray intermix drive tray The maximum number of drive trays that can be installed per path is 12. Product overview Hitachi Virtual Storage Platform G400, G600 Hardware Reference Guide...
  • Page 25: Hardware Description

    Hardware description The following sections describe the storage system hardware. Storage system controllers □ Controller interfaces □ Storage system drive trays □ Hitachi Virtual Storage Platform SVP server □ Hardware description Hitachi Virtual Storage Platform G400, G600 Hardware Reference Guide...
  • Page 26: Storage System Controllers

    When System Option Mode 1097 is set to ON, the WARNING LED does not blink even if the following failure information SIM issues failure information SIM: 452xxx, 462xxx, 3077xy, 4100xx and 410100. Hardware description Hitachi Virtual Storage Platform G400, G600 Hardware Reference Guide...
  • Page 27: Cblm Front Panel Without Bezel

    Item Description POWER ON/OFF (main switch) Powers the storage system. See the previous table. POWER, READY, WARNING, ALARM LEDs Controller 1 (bottom) and Controllers Controller 2 (top). Backup module Hardware description Hitachi Virtual Storage Platform G400, G600 Hardware Reference Guide...
  • Page 28: Cblm Rear Panel

    Off: Battery is not mounted, battery-mounting failure occurred, or firmware is being upgraded. Off is normal status for configurations with no batteries (for example, BKMF-10 and BKMF-20). CBLM rear panel Hardware description Hitachi Virtual Storage Platform G400, G600 Hardware Reference Guide...
  • Page 29 Number Item Power supply unit Front end module Back end module LAN blade Rear view (includes NAS modules) Hardware description Hitachi Virtual Storage Platform G400, G600 Hardware Reference Guide...
  • Page 30: Controller Interfaces

    Connect to Fibre Channel cables. STATUS LED Green: front end module is in power-on state. Red: front end module can be removed safely. PORT LED Red: Small form-factor pluggable can be removed. Hardware description Hitachi Virtual Storage Platform G400, G600 Hardware Reference Guide...
  • Page 31: Gbps Fibre Channel Board Leds And Connectors

    Port 2 Port 3 Port 4 CHB-1A CHB-1B CHB-1C CHB-1D CHB-1E CHB-1F CHB-1G CHB-1H CHB-2A CHB-2B CHB-2C CHB-2D CHB-2E CHB-2F CHB-2G CHB-2H 16 Gbps Fibre Channel board LEDs and connectors Hardware description Hitachi Virtual Storage Platform G400, G600 Hardware Reference Guide...
  • Page 32: Gbps Iscsi Board Leds And Connectors (Optical)

    CHB# Port 1 Port 2 CHB-1A CHB-1B CHB-1C CHB-1D CHB-1E CHB-1F CHB-1G CHB-1H CHB-2A CHB-2B CHB-2C CHB-2D CHB-2E CHB-2F CHB-2G CHB-2H 10 Gbps iSCSI board LEDs and connectors (optical) Hardware description Hitachi Virtual Storage Platform G400, G600 Hardware Reference Guide...
  • Page 33: Gbps Iscsi Board Leds And Connectors (Copper)

    Blue: Normal link status. Blink blue: Front end module is in communication status. iSCSI connectors Connect to Ethernet LAN cables. 10 Gbps iSCSI board LEDs and connectors (copper) Hardware description Hitachi Virtual Storage Platform G400, G600 Hardware Reference Guide...
  • Page 34: Lan Blade Leds And Connectors

    Green: link status is normal. LAN 2 LAN port used by the user. LAN 1 Maintenance LAN port used by service personnel. LAN ALARM LED Red: LAN blade can be removed. Hardware description Hitachi Virtual Storage Platform G400, G600 Hardware Reference Guide...
  • Page 35: Back End Module Leds And Connectors

    Drive trays contain drives, power supplies, fans, and status LEDs. They also provide interfaces for connecting to controllers and other drive trays. Small form factor (SFF) drive tray SFF with front panel bezel Hardware description Hitachi Virtual Storage Platform G400, G600 Hardware Reference Guide...
  • Page 36: Sff Front Panel Without Bezel

    The LED can be lit/turned off by Maintenance Utility to specify the chassis location. Lock Locks and unlocks the front panel bezel by using the supplied key. SFF front panel without bezel Hardware description Hitachi Virtual Storage Platform G400, G600 Hardware Reference Guide...
  • Page 37: Sff Rear Panel

    Connect to a controller or drive tray. Blue: OUT side port is linked PATH (OUT)LED PATH (OUT) connector Connect to a drive tray. Console This port is reserved. Power supply unit Hardware description Hitachi Virtual Storage Platform G400, G600 Hardware Reference Guide...
  • Page 38: Large Form Factor (Lff) Drive Tray

    • The LED can be lit/turned off by Maintenance Utility. Lock Locks and unlocks the front panel bezel by using the supplied key. LFF front panel without bezel Hardware description Hitachi Virtual Storage Platform G400, G600 Hardware Reference Guide...
  • Page 39: Lff Rear Panel

    Slots are designated the following way: 10 11 LFF rear panel Number Item Description POWER LED Green: ENC is in the power-on state. LOCATE LED Amber: Hardware description Hitachi Virtual Storage Platform G400, G600 Hardware Reference Guide...
  • Page 40: Flash Module Drive (Fmd) Tray

    Flash module drive (FMD) tray FMD with front panel bezel Number Item Description POWER LED Green: Drive tray is powered READY LED Green: Drive tray is operational. LOCATE LED Amber: Hardware description Hitachi Virtual Storage Platform G400, G600 Hardware Reference Guide...
  • Page 41: Fmd Front Panel Without Bezel

    DKC-F810I-1R6FN/3R2FN/ 6R4FN: flash module drive built-in capacitor is charged. If the storage system is turned on, the LED stops blinking when the capacitor is charged completely (about two minutes). Hardware description Hitachi Virtual Storage Platform G400, G600 Hardware Reference Guide...
  • Page 42: Fmd Rear Panel

    Red: ENC can be replaced. PATH (IN) LED Blue: IN side port is linked up. PATH (IN) connector Connect to a controller or drive tray. Blue: OUT side port is linked PATH (OUT)LED Hardware description Hitachi Virtual Storage Platform G400, G600 Hardware Reference Guide...
  • Page 43: Dense Intermix Drive Tray

    Green: Drive tray is operational. LOCATE LED Amber: • This LED indicates the location of the chassis. • The LED can be lit or turned off by the maintenance utility. Hardware description Hitachi Virtual Storage Platform G400, G600 Hardware Reference Guide...
  • Page 44: Dense Intermix Drive Tray Display Leds

    • Rear of drive tray: 48 - 59 • 36 - 47 • 24 - 35 • 12 - 23 • Front of drive tray: 00 - 11 Hardware description Hitachi Virtual Storage Platform G400, G600 Hardware Reference Guide...
  • Page 45: Dense Intermix Drive Tray Rear Panel

    This LED indicates the location of the chassis. • The LED can be lit or turned off by the maintenance utility. POWER LED Green: ENC is in the power-on state. Hardware description Hitachi Virtual Storage Platform G400, G600 Hardware Reference Guide...
  • Page 46: Sff And Lff Ac Power Supply Unit Leds And Connectors

    Service processor description VSP Gx00 models include a separate, dedicated 1U service processor (SVP) to host an element manager (Hitachi Device Manager - Storage Navigator). The SVP (model number 3919435.P) operates independently from the storage system's CPU and operating system, and provides out‑of‑band configuration and management of the storage system.
  • Page 47: Svp Front Panel

    • Applying Windows security patches. • Turning on automatic Windows updates or using the manual Windows update method. • Installing antivirus software that has been tested and approved by Hitachi. • Installing the latest SVP firmware releases from Hitachi. SVP front panel The SVP front panel has LEDs, a reset button, and a power button.
  • Page 48: Svp Rear Panel

    Note: After the Initial Startup Wizard is run, the SVP can be used in non- bridge mode. In this mode, the cables can be removed from SVP ports LAN3 and LAN4 and attached to switches. For more information, contact customer support. Hardware description Hitachi Virtual Storage Platform G400, G600 Hardware Reference Guide...
  • Page 49: System Option Modes

    System option modes System Option Modes □ System option modes Hitachi Virtual Storage Platform G400, G600 Hardware Reference Guide...
  • Page 50: System Option Modes

    The following table was up to date at the time this manual was published. However, the System Option Mode information might change in firmware releases that precede the next release of this manual. Contact your Hitachi Data Systems team for the latest information about System Option Modes.
  • Page 51 By specifying Split or Resync, Steady/Quick Split or Normal/ Quick Resync is respectively executed in accordance with Normal/Quick setting. For details, see the System Option Mode 122 sheet. System option modes Hitachi Virtual Storage Platform G400, G600 Hardware Reference Guide...
  • Page 52 Mode 448 = ON: (Enabled) If the SVP detects a blocked path, the SVP assumes that an error occurred, and then immediately splits (suspends) the mirror. Mode 448 = OFF: (Disabled) System option modes Hitachi Virtual Storage Platform G400, G600 Hardware Reference Guide...
  • Page 53 CLPRs (*a). (The larger the workload is, the larger the amount of the entire destage processing becomes.) (for HUS VM) System option modes Hitachi Virtual Storage Platform G400, G600 Hardware Reference Guide...
  • Page 54 System Option Mode 457 is ON, when selecting the external volume group and performing the LDEV format, any Write processing on the external LUs will be skipped. However, if System option modes Hitachi Virtual Storage Platform G400, G600 Hardware Reference Guide...
  • Page 55 75% or larger. Mode 467 is to prevent the dirty percentage from over 60% so that the host performance is not affected. System option modes Hitachi Virtual Storage Platform G400, G600 Hardware Reference Guide...
  • Page 56 Mode 471 = ON: This kind of SIMs is reported to maintenance personnel. Mode 471 = OFF: This kind of SIMs is not reported to maintenance personnel. Notes: System option modes Hitachi Virtual Storage Platform G400, G600 Hardware Reference Guide...
  • Page 57 5. While the mode is set to ON, make sure not to perform micro-program downgrade to an unsupported version. 6. While the mode is set to ON, make sure not to perform the Take Over function. System option modes Hitachi Virtual Storage Platform G400, G600 Hardware Reference Guide...
  • Page 58 IO operation is online and its performance requirement is severe. 2. Whether the disconnecting status for each external volume is progressed or not cannot be confirmed on System option modes Hitachi Virtual Storage Platform G400, G600 Hardware Reference Guide...
  • Page 59 Pending rate on RCU exceeds 60%. Mode 690 = OFF: Read JNL or JNL Restore is not prevented when the Write Pending rate on RCU exceeds 60% (the same as before). System option modes Hitachi Virtual Storage Platform G400, G600 Hardware Reference Guide...
  • Page 60 VMA set, the VMA information cannot be read. 4. When the mode is set to ON while the following conditions are met, the external volume is blocked. System option modes Hitachi Virtual Storage Platform G400, G600 Hardware Reference Guide...
  • Page 61 HDD must be unmounted and remounted. Notes: 1. When the RAID level or emulation type is changed for the existing parity group, this option should be applied only if System option modes Hitachi Virtual Storage Platform G400, G600 Hardware Reference Guide...
  • Page 62 Hitachi product is used as an external subsystem. 2. While USP V/VM is used as an external subsystem and its...
  • Page 63 Mode 733 = OFF: Volume Migration or Quick Restore operation during LDEV- related maintenance is not suspended. VSP and later models, HUS VM and later models: System option modes Hitachi Virtual Storage Platform G400, G600 Hardware Reference Guide...
  • Page 64 SIM (SIM-RC625000) is repeatedly reported every eight (8) hours until the pool usage rate falls below the depletion threshold. System option modes Hitachi Virtual Storage Platform G400, G600 Hardware Reference Guide...
  • Page 65 Characteristic1 item from SYMMETRIX is changed. (2) When CheckPaths or Device Health Check (1/hour) is performed, the information of an already-mapped external volume is updated to the one after change. System option modes Hitachi Virtual Storage Platform G400, G600 Hardware Reference Guide...
  • Page 66 3. When 0 data discarding is executed, load may be unbalanced among pool volumes. 4. Pool VOL deletion while the mode is set to ON fails. To delete pool VOLs, set the mode to OFF. System option modes Hitachi Virtual Storage Platform G400, G600 Hardware Reference Guide...
  • Page 67 (4) To apply the mode to TC Sync, both MCU and RCU must be HUS VM and micro-program must be the support version System option modes Hitachi Virtual Storage Platform G400, G600 Hardware Reference Guide...
  • Page 68 While a DP pool VOL is blocked, if a read or write I/O is issued to the blocked pool VOL, the DRU attribute is not set to Protect. System option modes Hitachi Virtual Storage Platform G400, G600 Hardware Reference Guide...
  • Page 69 - Usage rate of a parity group to which the copy target LDEV belongs is low. - ShadowImage copy progress is delayed. 2. This mode is available only when System Option Mode 467 is set to ON. System option modes Hitachi Virtual Storage Platform G400, G600 Hardware Reference Guide...
  • Page 70 The mode enables or disables the background format function performed on an unformatted area of a DP/DT/TI*1 pool. *1: The background format function for a TI pool is only available for V01+1 (73-01-31-00/00) or higher. System option modes Hitachi Virtual Storage Platform G400, G600 Hardware Reference Guide...
  • Page 71 Notes: 1. Apply the mode when the usage of upper tier is low and that of lower tier is high. System option modes Hitachi Virtual Storage Platform G400, G600 Hardware Reference Guide...
  • Page 72 I/O synchronous copy change as follows. Mode 899 = ON: System option mode 900 is ON: I/O synchronous copy starts without retrying Volume Migration. System option modes Hitachi Virtual Storage Platform G400, G600 Hardware Reference Guide...
  • Page 73 Tier Level ALL when the drive type of tier1 is SSD changes as follows. Mode 901 = ON: For tier1 (drive type is SSD), pages are allocated until the capacity reaches the limit. System option modes Hitachi Virtual Storage Platform G400, G600 Hardware Reference Guide...
  • Page 74 The number of pages to be migrated at tier relocation is set to up to one page per second. Mode 904 = OFF: No restriction on the number of pages to be migrated at tier relocation (existing specification). Notes: System option modes Hitachi Virtual Storage Platform G400, G600 Hardware Reference Guide...
  • Page 75 Mode 930 = ON: All of the zero data page reclamation operations in processing are stopped at once. (Also the zero data reclamation cannot be newly started.) Mode 930 = OFF: System option modes Hitachi Virtual Storage Platform G400, G600 Hardware Reference Guide...
  • Page 76 8. Before downgrading the micro-program to an unsupported version, set system option mode 937 to OFF and wait for at least 30 minutes. System option modes Hitachi Virtual Storage Platform G400, G600 Hardware Reference Guide...
  • Page 77 Mode 1093 = ON: Background unmap cannot work. Mode 1093 = OFF (default): Background unmap can work. System option modes Hitachi Virtual Storage Platform G400, G600 Hardware Reference Guide...
  • Page 78 Mode 1097 = OFF (default): When SIM=452XXX, 462XXX, 3077XY, 4100XX, or 410100 is reported, the warning LED blinks. Note: The mode disables the warning LED to blink when specific SIMs are reported. System option modes Hitachi Virtual Storage Platform G400, G600 Hardware Reference Guide...
  • Page 79: Maintaining The Storage System

    This chapter describes topics for performing storage system maintenance. Storing the storage system □ Using flash module drives □ Powering off the storage system □ Removing cables □ Maintaining the storage system Hitachi Virtual Storage Platform G400, G600 Hardware Reference Guide...
  • Page 80: Storing The Storage System

    Follow the guidelines to avoid damaging the components when handling FMDs. • Check the main edge connector of the drive for any damage, deformation, dust or debris before installing. Maintaining the storage system Hitachi Virtual Storage Platform G400, G600 Hardware Reference Guide...
  • Page 81: Powering Off The Storage System

    Observe the following instructions when removing cables form the storage system. To remove a SAS cable, pull the tab of the SAS cable (1) to release the latch and remove the SAS cable (2). Maintaining the storage system Hitachi Virtual Storage Platform G400, G600 Hardware Reference Guide...
  • Page 82 (1) to release the latch and remove the SAS cable (2). To remove a LAN cable, push the top of the LAN cable connector (1) to release the latch and remove the LAN cable (2). Maintaining the storage system Hitachi Virtual Storage Platform G400, G600 Hardware Reference Guide...
  • Page 83: User Administration For Maintenance Utility

    User administration for maintenance utility The maintenance utility allows you to set up and manage user accounts. When NAS Modules are installed, see Hitachi NAS Platform System Access Guide. Required roles for operating Maintenance Utility □ Setting up user accounts □...
  • Page 84: Required Roles For Operating Maintenance Utility

    Boot System Safe Mode Support Personnel* Alert Display Support Personnel or User Maintenance* Alert Display Related to FRU Support Personnel or User Maintenance* Administration Menu Power Management System Management User administration for maintenance utility Hitachi Virtual Storage Platform G400, G600 Hardware Reference Guide...
  • Page 85: Setting Up User Accounts

    Administration. In the User Groups tab, click Create User. Create a new user account. Specify the User Name, Account Status, Authentication and User Group. Click Finish. User administration for maintenance utility Hitachi Virtual Storage Platform G400, G600 Hardware Reference Guide...
  • Page 86 The following methods are available: Local = does not use authentication server. Uses a dedicated password for storage management software. External = uses an authentication server. User administration for maintenance utility Hitachi Virtual Storage Platform G400, G600 Hardware Reference Guide...
  • Page 87: Disabling User Accounts

    Procedure In the Maintenance Utility window, click Administration > User Administration. In the User Groups tab, click the user group to which the user belongs. User administration for maintenance utility Hitachi Virtual Storage Platform G400, G600 Hardware Reference Guide...
  • Page 88 Click the Users tab, and then select the user that you want to disable. Click Edit. For Account Status, click Disable, and then click Finish. User administration for maintenance utility Hitachi Virtual Storage Platform G400, G600 Hardware Reference Guide...
  • Page 89 Confirm the settings, and then click Apply. User administration for maintenance utility Hitachi Virtual Storage Platform G400, G600 Hardware Reference Guide...
  • Page 90 When a completion message appears, click Close. User administration for maintenance utility Hitachi Virtual Storage Platform G400, G600 Hardware Reference Guide...
  • Page 91: Removing User Accounts

    After deletion, click Edit to enable the user account. Procedure In the Maintenance Utility window, click Administration > User Administration. In the User Groups tab, click the user group to which the user belongs. User administration for maintenance utility Hitachi Virtual Storage Platform G400, G600 Hardware Reference Guide...
  • Page 92 Click the Users tab, and then select the user you want to remove. Click Remove. The Confirm window opens. User administration for maintenance utility Hitachi Virtual Storage Platform G400, G600 Hardware Reference Guide...
  • Page 93 In the Confirm window, confirm the settings and specify the task name, and then click Apply. At the completion message, click Close. User administration for maintenance utility Hitachi Virtual Storage Platform G400, G600 Hardware Reference Guide...
  • Page 94: Backing Up User Accounts

    Restoring user account information Procedure Click User Account Information > Restore The Restore User Account window opens. Specify file names to be restored, and then click Apply. User administration for maintenance utility Hitachi Virtual Storage Platform G400, G600 Hardware Reference Guide...
  • Page 95 When a completion message appears, click Close. User administration for maintenance utility Hitachi Virtual Storage Platform G400, G600 Hardware Reference Guide...
  • Page 96 User administration for maintenance utility Hitachi Virtual Storage Platform G400, G600 Hardware Reference Guide...
  • Page 97: Storage System Specifications

    Environmental specifications □ Battery specifications □ RAID specifications □ iSCSI specifications □ iSCSI standards □ Regulatory compliance □ Dense intermix drive tray connection restrictions □ SVP hardware specifications □ Storage system specifications Hitachi Virtual Storage Platform G400, G600 Hardware Reference Guide...
  • Page 98: Model Lists

    DW-F800-2HS10B Front end module (10-Gbps 2-16 copper iSCSI copper) DW-F800-NAS NAS_Module DW-F800-BS12G Back end module DKC-F810I-1PS8 SFP for 8-Gbps shortwave 0-64 DKC-F810I-1PL8 SFP for 8 -Gbps longwave 0-64 Storage system specifications Hitachi Virtual Storage Platform G400, G600 Hardware Reference Guide...
  • Page 99: Drive Tray Model Lists

    600-GB, 2.5-inch, 15kmin , 6- 0-24 Gbps SAS drive DKC-F810I-1R2JCMC 1.2-TB, 2.5-inch, 10kmin , 6- 0-24 Gbps SAS drive DKC-F810I-1R8JGM 1.8-TB, 2.5-inch, 10kmin , 6- 0-24 Gbps SAS drive Storage system specifications Hitachi Virtual Storage Platform G400, G600 Hardware Reference Guide...
  • Page 100 1 k byte =1,024 bytes. FMD drive tray components Model number Part name Quantity DW-F800-DBF 2U chassis Power supply unit Power cable (0.9 m) Power cable (2.5 m) Front bezel (2U) Storage system specifications Hitachi Virtual Storage Platform G400, G600 Hardware Reference Guide...
  • Page 101 1.8-TB, 3.5-inch, 10kmin , 6- 0-60 Gbps SAS drive DKC-F810I-4R0H4M 4-TB, 7.2K 3.5-inch, 7200min 0-60 6-Gbps SAS drive (contains BNST) DKC-F810I-4R0H4MC 4-TB, 7.2K 3.5-inch, 7200min 0-60 6-Gbps SAS drive Storage system specifications Hitachi Virtual Storage Platform G400, G600 Hardware Reference Guide...
  • Page 102: Other Model List

    Optical cables Model number Specification A-6515-GM5L 5 m LC-LC optical cable for optical A-6515-GM10L 10 m LC-LC optical cable for optical A-6515-GM20L 20 m LC-LC optical cable for optical Storage system specifications Hitachi Virtual Storage Platform G400, G600 Hardware Reference Guide...
  • Page 103: Replacement Parts

    300 m LC-LC optical cable for optical Replacement parts Part replacement is required to maintain high performance. Replacement of parts is covered by the maintenance service contract. Battery unit Replacement period Three years. Storage system specifications Hitachi Virtual Storage Platform G400, G600 Hardware Reference Guide...
  • Page 104: Vsp G400 And Vsp G600 Mechanical Specifications

    196.92, 288.20, 393.85, 576.39, 1152.79, 1729.29 3.5-inch drive (LFF and dense intermix 393.85, 1152.79, 1729.29, 3916.14, 5874.22 drive tray) Flash Module Drive (flash module 1759.21, 3518.43 , 7036.87 drive tray) Rotational speed (min Storage system specifications Hitachi Virtual Storage Platform G400, G600 Hardware Reference Guide...
  • Page 105: Host Interface

    10 Gbps (iSCSI copper) NAS module (Fibre Channel) 1000 Mbs Number of ports 8-Gbps Fibre Channel optical 16-Gbps Fibre Channel optical 10-Gbps optical iSCSI 10-Gbps copper iSCSI Storage system specifications Hitachi Virtual Storage Platform G400, G600 Hardware Reference Guide...
  • Page 106 2048 targets Maximum volumes/parity groups 2048 Shared memory and data assurance Item Specification Flash memory 32 M bytes L3 Cache memory 4 M bytes SDRAM 1 G bytes Storage system specifications Hitachi Virtual Storage Platform G400, G600 Hardware Reference Guide...
  • Page 107 Approx 50.70 inches (23 kg) Approx 59.52 inches (27 kg) Aprox. 83.77 pounds (38 kg) Dense intermix drive tray Approx. 198.41 pounds (90 kg) Required height Component Specification CBLM Storage system specifications Hitachi Virtual Storage Platform G400, G600 Hardware Reference Guide...
  • Page 108 If the storage system is not charged for more than six months, the battery can become overcharged and sustain unrecoverable damage. To avoid this situation, charge the battery more than 3 hours every six months. Insulation performance Storage system specifications Hitachi Virtual Storage Platform G400, G600 Hardware Reference Guide...
  • Page 109: Electrical Specifications

    If one power unit fails, another power unit requires electric current for the two power units. Therefore, plan the power supply facility so that the current-carrying capacity for one power unit can provide the total capacity for two power units. Storage system specifications Hitachi Virtual Storage Platform G400, G600 Hardware Reference Guide...
  • Page 110: Environmental Specifications

    14°F to 95°F (-10°C to 35°C) (-10°C to 50°C) Transport, storage -22°F to 140°F -22°F to 122°F (-30°C to 50°C) (-30°C to 60°C) Temperature 10 or less change rate (°C/h) Storage system specifications Hitachi Virtual Storage Platform G400, G600 Hardware Reference Guide...
  • Page 111 900 (Environmental temperature: 10°C to 35°C) when DKC-F710I-1R6FM or DKC-F710I-3R2FM drive is installed. (Environmental temperature: 10°C to 40°C) 3,000 3,000 (Environmental temperature: 10°C to 32°C) Operating (m) (Environmental Storage system specifications Hitachi Virtual Storage Platform G400, G600 Hardware Reference Guide...
  • Page 112: Acoustic Noise

    Acoustic power level (LwA) measured by the ISO 7779 standard is 7.2 B. This value changes from 7.2 B to 8.1 B, according to the ambient temperature, drive configuration, and operating status. Storage system specifications Hitachi Virtual Storage Platform G400, G600 Hardware Reference Guide...
  • Page 113: Battery Specifications

    RAID specifications SFF, LFF, dense Item Controller intermix drive trays (range for setup) RAID level SAS, SAS 7.2 krpm, flash drives mounted: 0, 1, 5, 6, 1+0 (DBW Storage system specifications Hitachi Virtual Storage Platform G400, G600 Hardware Reference Guide...
  • Page 114: Iscsi Specifications

    2 per interface board per iSCSI system Connection methods Direct and switch connections Host connections 255 (maximum per iSCSI port) With Linux software initiator, the maximum number decreases. Storage system specifications Hitachi Virtual Storage Platform G400, G600 Hardware Reference Guide...
  • Page 115 IPv6 router is connected to the same network, and then set IPv6 global address automatically. Subnet mask Supported Gateway address Supported DHCP Ping (ICMP ECHO) Transmit, Supported Receive Storage system specifications Hitachi Virtual Storage Platform G400, G600 Hardware Reference Guide...
  • Page 116 CHAP user registration Max 512 users per iSCSI port iSNS Supported With iSNS (name service), a host can discover a target without knowing the target's IP address. Storage system specifications Hitachi Virtual Storage Platform G400, G600 Hardware Reference Guide...
  • Page 117: Iscsi Standards

    Standard Specification Mark on the product Country regulation Electronic emission FCC part 15 Subpart B: USA and Canada controls 2013 ICES-003 Issue 5:2012 ICES-003 USA and Canada Storage system specifications Hitachi Virtual Storage Platform G400, G600 Hardware Reference Guide...
  • Page 118: Dense Intermix Drive Tray Connection Restrictions

    (SVP) server. Caution: The HDS supplied SVP server is not supported in high temperature environments. Do not operate the SVP server at temperatures of 40°C or higher. Storage system specifications Hitachi Virtual Storage Platform G400, G600 Hardware Reference Guide...
  • Page 119 Canada - CUL listed • Germany - TUV Certified • Europe/CE Mark • EN 60950/IEC 60950-Compliant Fans 2x 4cm 4-pin PWM fans Operating system Microsoft Windows Embedded Standard 7 Storage system specifications Hitachi Virtual Storage Platform G400, G600 Hardware Reference Guide...
  • Page 120 Storage system specifications Hitachi Virtual Storage Platform G400, G600 Hardware Reference Guide...
  • Page 121: Index

    40 tray 118 large form factor drive tray 38 connections service processor 47 dense intermix drive tray restrictions 118 small form factor drive tray 35 controllers CBLM 26 Index Hitachi Virtual Storage Platform G400, G600 Hardware Reference Guide...
  • Page 122 117 removing cables 81 removing user accounts 91 replacement parts 103 restoring user account information 94 roles 84 SAS cables removing 81 scalability 22 service processor front panel 47 Index Hitachi Virtual Storage Platform G400, G600 Hardware Reference Guide...
  • Page 123 Hitachi Virtual Storage Platform G400, G600 Hardware Reference Guide...
  • Page 124 Hitachi Data Systems Corporate Headquarters 2845 Lafayette Street Santa Clara, California 95050-2639 U.S.A. www.hds.com Regional Contact Information Americas +1 408 970 1000 info@hds.com Europe, Middle East, and Africa +44 (0) 1753 618000 info.emea@hds.com Asia Pacific +852 3189 7900 hds.marketing.apac@hds.com MK-94HM8022-05...

This manual is also suitable for:

G400

Table of Contents