Hitachi G200 Hardware Reference Manual

Hitachi G200 Hardware Reference Manual

Virtual storage platform
Hide thumbs Also See for G200:
Table of Contents

Advertisement

Hitachi Virtual Storage Platform G200
Hardware Reference Guide
MK-94HM8020-09
May 2017

Advertisement

Table of Contents
loading

Summary of Contents for Hitachi G200

  • Page 1 Hitachi Virtual Storage Platform G200 Hardware Reference Guide MK-94HM8020-09 May 2017...
  • Page 2 Materials. “Materials” mean text, data, photographs, graphics, audio, video and documents. Hitachi reserves the right to make changes to this Material at any time without notice and assumes no responsibility for its use. The Materials contain the most current information available at the time of publication.
  • Page 3: Table Of Contents

    Document conventions................... 13 Conventions for storage capacity values..............15 Accessing product documentation................15 Getting help......................15 Comments......................16 1 Hitachi Virtual Storage Platform G200 hardware overview....... 17 Block configuration....................18 VSP G200 model....................18 Features........................ 19 Scalability......................20 Examples of supported VSP G200 configurations..........20 Maximum number of mounted drive trays............21...
  • Page 4 SFF and LFF DC power supply unit LEDs and connectors...........57 5 Host port expansion chassis..............59 Host port expansion chassis front panel bezel LEDs..........60 PCIe switchboard....................60 Host port expansion chassis fan................61 PCIe cable connector....................61 Hitachi Virtual Storage Platform G200 Hardware Reference Guide...
  • Page 5 B VSP G200 storage system specifications..........89 C VSP G200 storage system mechanical specifications....... 93 VSP G200 mechanical specifications (AC power supply model)........94 VSP G200 mechanical specifications (DC power supply model)........99 D Electrical specifications for VSP G200...........105 Electrical specifications..................106 VSP G200 electrical specifications (DC power supply)..........
  • Page 6 H Regulatory compliance............... 123 Index....................125 Hitachi Virtual Storage Platform G200 Hardware Reference Guide...
  • Page 7: Preface

    Intended audience □ Product version □ Release notes □ Changes in this revision □ Document conventions □ Conventions for storage capacity values □ Accessing product documentation □ Getting help □ Comments □ Preface Hitachi Virtual Storage Platform G200 Hardware Reference Guide...
  • Page 8: Safety And Environmental Notices

    Backup Hitachi cannot guarantee against data loss due to failures. Therefore, back up your data to minimize chances for data loss. Data backup is also critical when hardware components are added or replaced, because performing such hardware procedures restores parameter settings that can affect how data is managed on the storage systems.
  • Page 9: Equipment With Nebs Specifications

    DAMAGE. Notes on use When using the Hitachi storage system, be sure to read this guide and understand the operating procedures and instructions described herein thoroughly before staring your operation. The array complies with FDA radiation performance standard 21 CFR subchapter J.
  • Page 10: General Safety Guidelines

    • Before starting work, know where the emergency off switches are located and know how to operate them. Preface Hitachi Virtual Storage Platform G200 Hardware Reference Guide...
  • Page 11: Avoiding Rotating Or Moving Parts

    • Stop the power feed to the equipment and inform the system administrator immediately if you notice an unusual smell, abnormal heat generation, or smoke emission. Leaving such conditions unattended can cause electric shock or fire. Preface Hitachi Virtual Storage Platform G200 Hardware Reference Guide...
  • Page 12: Emergency Procedures

    • Turn off the emergency power switch or stop the power supply to the storage system. • If the fire continues to burn after the power is turned off, take necessary actions such as using a fire extinguisher or contacting the fire department. Preface Hitachi Virtual Storage Platform G200 Hardware Reference Guide...
  • Page 13: Intended Audience

    Intended audience This document is intended for Hitachi Data Systems representatives and authorized service providers who install, configure, or operate storage systems. Readers of this document should be familiar with the following: • Data processing and RAID storage systems and their basic functions.
  • Page 14 Warns the user of adverse conditions and/or consequences (for example, disruptive operations, data loss, or a system crash). WARNING Warns the user of a hazardous situation which, if not avoided, could result in death or serious injury. Preface Hitachi Virtual Storage Platform G200 Hardware Reference Guide...
  • Page 15: Conventions For Storage Capacity Values

    Getting help Hitachi Data Systems Support Connect is the destination for technical support of products and solutions sold by Hitachi Data Systems. To contact technical Preface Hitachi Virtual Storage Platform G200 Hardware Reference Guide...
  • Page 16: Comments

    Hitachi Data Systems Support Connect for contact information: https://support.hds.com/en_us/contact-us.html. Hitachi Data Systems Community is a global online community for HDS customers, partners, independent software vendors, employees, and prospects. It is the destination to get answers, discover insights, and make connections.
  • Page 17: Hitachi Virtual Storage Platform G200 Hardware Overview

    Hitachi Virtual Storage Platform G200 hardware overview The Hitachi Virtual Storage Platform G200 is a modular, rack-mountable, storage system. The storage systems contain dual controllers for communicating with a data host. Each controller contains its own processor, dual in-line cache memory modules (DIMMs), cache flash memory (CFM), battery, and fans.
  • Page 18: Block Configuration

    (SFF) disk drives or 12 large form factor (LFF) disk drives. • An associated number of drive trays. The VSP G200 supports 64 GB of high-speed memory cache, arranged as 32 GB per controller. The VSP G200 interfaces consist of: •...
  • Page 19: Features

    DB60C Related references • Examples of supported VSP G200 configurations on page 20 Features The features described in the table are included with VSP G200. Feature Value Maximum cache memory supported 64 GB Maximum number of spare drives Maximum number of RAID groups...
  • Page 20: Scalability

    Scalability All storage systems offer pay-as-you-grow scalability by allowing you to hot- add drives as you need them. Examples of supported VSP G200 configurations The VSP G200 controller chassis provides a built-in compartment for installing drives. Maximum number of Maximum number of...
  • Page 21: Maximum Number Of Mounted Drive Trays

    VSP G200 Controller SFF drive + LFF drive + Dense SFF, LFF dense dense intermix drive drives intermix drive intermix tray tray drive tray CBSS Hitachi Virtual Storage Platform G200 hardware overview Hitachi Virtual Storage Platform G200 Hardware Reference Guide...
  • Page 22 1152 CBSS/CBSL 1140 1176 1164 1200 1188 1224 1212 1248 1236 1272 1260 1296 1008 1284 1032 Hitachi Virtual Storage Platform G200 hardware overview Hitachi Virtual Storage Platform G200 Hardware Reference Guide...
  • Page 23 1320 1080 1308 1104 1344 1152 1332 1176 1368 1224 1356 1248 1392 1296 1380 1320 1416 1368 1404 1392 1440 1440 Hitachi Virtual Storage Platform G200 hardware overview Hitachi Virtual Storage Platform G200 Hardware Reference Guide...
  • Page 24 Hitachi Virtual Storage Platform G200 hardware overview Hitachi Virtual Storage Platform G200 Hardware Reference Guide...
  • Page 25: Virtual Storage Platform G200 Controllers

    Virtual Storage Platform G200 controllers The Virtual Storage Platform G200 model equipped with dual controllers for communicating with a data host. Each controller contains its own processor, dual in-line cache memory modules (DIMMs), cache flash memory (CFM), battery, and fans. The controller has an Ethernet connection for out-of-band management using Hitachi Device Manager - Storage Navigator.
  • Page 26: Cbss Controller

    LED might turn off during user maintenance. ALARM LED Off: Normal operation. Red: Processor failure (system might be down). Go to the Customer Contact Us page at Virtual Storage Platform G200 controllers Hitachi Virtual Storage Platform G200 Hardware Reference Guide...
  • Page 27: Cbss Front Panel Without Bezel

    (SIM) are issued: 452xxx, 462xxx, 3077xx, 4100xx, and 410100. POWER ON/OFF (main switch) Powers the storage system. Small form factor drives The twenty-four 2.5-inch small form factor drives are Virtual Storage Platform G200 controllers Hitachi Virtual Storage Platform G200 Hardware Reference Guide...
  • Page 28: Cbss Rear Panel

    Restoring, or sequential shutdown in progress. CTL WARN LED Amber blink one time: Failure with fan 0. Amber blink two times: Failure with fan 1. Cache flash memory Virtual Storage Platform G200 controllers Hitachi Virtual Storage Platform G200 Hardware Reference Guide...
  • Page 29: Cbss/Cbsl Ac Power Supply Unit Leds And Connectors

    Power supply unit CBSS/CBSL AC power supply unit LEDs and connectors The following table describes the definitions of the CBSS and CBSL AC power supply unit LEDs and connectors. Virtual Storage Platform G200 controllers Hitachi Virtual Storage Platform G200 Hardware Reference Guide...
  • Page 30: Cbssd/Cbsld Dc Power Supply Unit Leds And Connectors

    CBSL with front panel bezel The following table describes the definitions of the CBSL controller front panel bezel LEDs. Virtual Storage Platform G200 controllers Hitachi Virtual Storage Platform G200 Hardware Reference Guide...
  • Page 31 Note: Removing a controller can cause the POWER, READY, WARNING, and ALARM LEDs on the front panel to turn off. These LEDs return to their on state after the storage system recovers from the controller replacement. Virtual Storage Platform G200 controllers Hitachi Virtual Storage Platform G200 Hardware Reference Guide...
  • Page 32: Cbsl Front Panel Without Bezel

    The slots are organized in the following order: 10 11 CBSL rear panel The following table describes the definitions of the CBSL controller rear panel LEDs. Virtual Storage Platform G200 controllers Hitachi Virtual Storage Platform G200 Hardware Reference Guide...
  • Page 33 Maintenance LAN port (left) and user LAN port (right). Uninterruptible power supply (UPS) port ALARM LED (for cache flash memory) Red: Cache flash memory can be removed. Backup module Virtual Storage Platform G200 controllers Hitachi Virtual Storage Platform G200 Hardware Reference Guide...
  • Page 34: Cbss/Cbsl Ac Power Supply Unit Leds And Connectors

    LEDs and connectors. Number Item Description Receptacle Connects to the power cable provided with the storage system. AC IN LED Blue: AC input is normal. Virtual Storage Platform G200 controllers Hitachi Virtual Storage Platform G200 Hardware Reference Guide...
  • Page 35: Cbssd/Cbsld Dc Power Supply Unit Leds And Connectors

    LEDs and connectors. Number Item Description ALM/RDY LED Red: Power supply unit can be replaced. Green: Normal operation. DC IN LED Blue: DC input is normal. Virtual Storage Platform G200 controllers Hitachi Virtual Storage Platform G200 Hardware Reference Guide...
  • Page 36 Virtual Storage Platform G200 controllers Hitachi Virtual Storage Platform G200 Hardware Reference Guide...
  • Page 37: Host, Network, And Drive Tray Ports And Leds

    LEDs display the operating status of the storage system. Front end module descriptions □ LAN blade LEDs and connectors □ Back end module LEDs and connectors □ Host, Network, and Drive Tray Ports and LEDs Hitachi Virtual Storage Platform G200 Hardware Reference Guide...
  • Page 38: Front End Module Descriptions

    Blue: Normal link status. Blink blue: Front end module is in communication status. iSCSI connectors Connect to Ethernet LAN cables. 10-Gbps iSCSI board LEDs and connectors (copper) Host, Network, and Drive Tray Ports and LEDs Hitachi Virtual Storage Platform G200 Hardware Reference Guide...
  • Page 39: 8-Gbps, 16-Gbps, Or 32-Gbps Fibre Channel (4-Port) Board Leds And Connectors

    Off: No link connection or not ready to communicate. iSCSI connectors Connect to Ethernet LAN cables. 8-Gbps, 16-Gbps, or 32-Gbps Fibre Channel (4-port) board LEDs and connectors Host, Network, and Drive Tray Ports and LEDs Hitachi Virtual Storage Platform G200 Hardware Reference Guide...
  • Page 40 Red: Small form factor pluggable can be removed. Blue: Normal link status at 16- Gbps (16-Gbps). Blue: Normal link status at 32- Gbps (32-Gbps). Host, Network, and Drive Tray Ports and LEDs Hitachi Virtual Storage Platform G200 Hardware Reference Guide...
  • Page 41: 16-Gbps Fibre Channel (2-Port) Board Leds And Connectors

    CHB-1A CHB-1B CHB-1C CHB-1D CHB-1E CHB-1F CHB-1G CHB-1H CHB-2A CHB-2B CHB-2C CHB-2D CHB-2E CHB-2F CHB-2G CHB-2H 16-Gbps Fibre Channel (2-port) board LEDs and connectors Host, Network, and Drive Tray Ports and LEDs Hitachi Virtual Storage Platform G200 Hardware Reference Guide...
  • Page 42: Lan Blade Leds And Connectors

    Port 1 Port 2 CHB-1A CHB-1B CHB-1C CHB-1D CHB-1E CHB-1F CHB-1G CHB-1H CHB-2A CHB-2B CHB-2C CHB-2D CHB-2E CHB-2F CHB-2G CHB-2H LAN blade LEDs and connectors Host, Network, and Drive Tray Ports and LEDs Hitachi Virtual Storage Platform G200 Hardware Reference Guide...
  • Page 43: Back End Module Leds And Connectors

    Uninterruptible power supply (UPS) port Back end module LEDs and connectors The back end module LEDs display the operating status of the module. Host, Network, and Drive Tray Ports and LEDs Hitachi Virtual Storage Platform G200 Hardware Reference Guide...
  • Page 44 Number Item Description PATH 1 connector Connects to a drive tray. PORT LED Blue: Normal link status. Host, Network, and Drive Tray Ports and LEDs Hitachi Virtual Storage Platform G200 Hardware Reference Guide...
  • Page 45: Storage System Drive Trays

    □ Dense intermix drive tray □ SFF and LFF AC power supply unit LEDs and connectors □ SFF and LFF DC power supply unit LEDs and connectors □ Storage system drive trays Hitachi Virtual Storage Platform G200 Hardware Reference Guide...
  • Page 46: Small Form-Factor (Sff) Drive Tray

    Can be turned on or turned off by the maintenance utility. Lock Locks and unlocks the front panel bezel by using the supplied key. SFF front panel without bezel Storage system drive trays Hitachi Virtual Storage Platform G200 Hardware Reference Guide...
  • Page 47: Sff Rear Panel

    Small form factor drives The twenty-four 2.5-inch small form factor drives are positioned vertically. The slots are organized from 0 to 23. SFF rear panel Storage system drive trays Hitachi Virtual Storage Platform G200 Hardware Reference Guide...
  • Page 48: Large Form-Factor (Lff) Drive Tray

    AC IN LED Green: Normal operation. ALM LED Red: Power supply unit can be replaced. RDY LED Green: Normal operation. Large form-factor (LFF) drive tray LFF with front panel bezel Storage system drive trays Hitachi Virtual Storage Platform G200 Hardware Reference Guide...
  • Page 49: Lff Front Panel Without Bezel

    LFF front panel without bezel Number Item Description POWER, READY, and LOCATE LEDs Green: Drive tray is powered Green: Drive tray is operational. Amber: Storage system drive trays Hitachi Virtual Storage Platform G200 Hardware Reference Guide...
  • Page 50: Lff Rear Panel

    Can be turned on or turned off by the maintenance utility. ALARM LED Red: ENC can be replaced. PATH (IN) LED Blue: IN side port is linked up. Storage system drive trays Hitachi Virtual Storage Platform G200 Hardware Reference Guide...
  • Page 51: Flash Module Drive (Fmd) Tray

    READY LED Green: Drive tray is operational. LOCATE LED Amber: • Indicates the location of the chassis. • Can be turned on or turned off by the maintenance utility. Storage system drive trays Hitachi Virtual Storage Platform G200 Hardware Reference Guide...
  • Page 52: Fmd Front Panel Without Bezel

    If the storage system is turned on, the LED stops blinking when the capacitor is finished charging (approximately two minutes). Note: ACT indicator is only printed on some types of FMDs. Storage system drive trays Hitachi Virtual Storage Platform G200 Hardware Reference Guide...
  • Page 53: Fmd Rear Panel

    9, 10, 11 6, 7, 8 3, 4, 5 0, 1, 2 FMD rear panel Number Item Description POWER LED Green: ENC is in the power-on state. LOCATE LED Amber: Storage system drive trays Hitachi Virtual Storage Platform G200 Hardware Reference Guide...
  • Page 54: Dense Intermix Drive Tray

    Green: Power supply unit is AC IN LED operating normally. ALM REPLACE LED Red: Power supply unit can be replaced. Dense intermix drive tray Dense intermix drive tray with front panel bezel Storage system drive trays Hitachi Virtual Storage Platform G200 Hardware Reference Guide...
  • Page 55: Dense Intermix Drive Tray Display Leds

    Dense intermix drive tray display LEDs Number Item Description Green: Normal operation. Blink green: Drive is being accessed. ALM LED Red: Drive stopped due to a failure and can be replaced. Storage system drive trays Hitachi Virtual Storage Platform G200 Hardware Reference Guide...
  • Page 56: Dense Intermix Drive Tray Rear Panel

    PATH (OUT) connector Connect to a drive tray. PATH (IN) LED Blue: IN side port is linked up. PATH (IN) connector Connects to a controller or drive tray. Storage system drive trays Hitachi Virtual Storage Platform G200 Hardware Reference Guide...
  • Page 57: Sff And Lff Ac Power Supply Unit Leds And Connectors

    SFF and LFF DC power supply unit LEDs and connectors Both SFF and LFF drive trays are equipped with DC power supply units. The DC power supply units include LEDs to display its operating status. Storage system drive trays Hitachi Virtual Storage Platform G200 Hardware Reference Guide...
  • Page 58 Number Item Description Green: Normal operation. RDY LED Green: DC input is operating DC IN LED normally. Red: Power supply unit can be ALM LED replaced. Storage system drive trays Hitachi Virtual Storage Platform G200 Hardware Reference Guide...
  • Page 59: Host Port Expansion Chassis

    Host port expansion chassis front panel bezel LEDs □ PCIe switchboard □ Host port expansion chassis fan □ PCIe cable connector □ Host port expansion chassis power supply □ Host port expansion chassis Hitachi Virtual Storage Platform G200 Hardware Reference Guide...
  • Page 60: Host Port Expansion Chassis Front Panel Bezel Leds

    Green: Host port expansion is POWER LED turned on. Amber: PCIe module is turned Off: PCIe module is turned off. Lock or unlock the front bezel. Safety lock PCIe switchboard Host port expansion chassis Hitachi Virtual Storage Platform G200 Hardware Reference Guide...
  • Page 61: Host Port Expansion Chassis Fan

    Off: PCIe switchboard is powered off. Host port expansion chassis fan Number Item Description ALM LED Red: Fan failure has occurred. Off: Normal operation. PCIe cable connector Host port expansion chassis Hitachi Virtual Storage Platform G200 Hardware Reference Guide...
  • Page 62 Off: Basic PCIe is normal or not set. Link Option LED Green: Option PCIe Gen-3.0 (8- Gbps) is linked up normally. Off: Option PCIe is not linked up (PCIe cable might not be Host port expansion chassis Hitachi Virtual Storage Platform G200 Hardware Reference Guide...
  • Page 63: Host Port Expansion Chassis Power Supply

    Host port expansion chassis power supply Number Item Description ALM/RDY LED Red: Host port expansion chassis power supply can be replaced safely. Green: Normal operation. AC IN LED Blue: AC input is normal. Host port expansion chassis Hitachi Virtual Storage Platform G200 Hardware Reference Guide...
  • Page 64 Host port expansion chassis Hitachi Virtual Storage Platform G200 Hardware Reference Guide...
  • Page 65: Vsp Service Processor Server

    The SVP is available as: • A physical 1U management server provided by Hitachi Data Systems that runs Windows Embedded Standard 7. • A software application that runs Windows 7 Professional x64 Service Pack 1 (64-bit) on a customer-supplied server hardware, a VMware ESXi host, or Linux KVM host.
  • Page 66: Service Processor Description

    • Turning on automatic Windows updates or using the manual Windows update method. • Installing antivirus software that has been tested and approved by Hitachi. SVP front panel The front panel of the physical SVP is equipped with LEDs, a reset button, and a power button.
  • Page 67: Svp Rear Panel

    LAN ports. Number Description Power socket. Attach the power cable supplied with the SVP. Four LAN ports arranged as follows: LAN3 LAN4 LAN1 LAN2 VSP service processor server Hitachi Virtual Storage Platform G200 Hardware Reference Guide...
  • Page 68: Service Processor Hardware Specifications

    Hard drive 2 TB Network interface card x4 ports (on-board NIC) + x1 IPMI (BMC) port Fans 2 x 4-cm 4-pin PWM fans Operating system Windows Embedded Standard 7 VSP service processor server Hitachi Virtual Storage Platform G200 Hardware Reference Guide...
  • Page 69: Maintaining The Storage System

    For more complex maintenance activities, contact customer support. Storing the storage system □ Using flash module drives □ Powering off the storage system □ Removing cables □ Maintaining the storage system Hitachi Virtual Storage Platform G200 Hardware Reference Guide...
  • Page 70: Storing The Storage System

    Follow the guidelines to avoid damaging the components when handling FMDs. • Check the main edge connector of the drive for any damage, deformation, dust, or debris before installing. Maintaining the storage system Hitachi Virtual Storage Platform G200 Hardware Reference Guide...
  • Page 71: Powering Off The Storage System

    Observe the following instructions when removing cables form the storage system. To remove a SAS cable, pull the tab of the SAS cable (1) to release the latch and remove the SAS cable (2). Maintaining the storage system Hitachi Virtual Storage Platform G200 Hardware Reference Guide...
  • Page 72 (1) to release the latch and remove the SAS cable (2). To remove a LAN cable, push the top of the LAN cable connector (1) to release the latch and remove the LAN cable (2). Maintaining the storage system Hitachi Virtual Storage Platform G200 Hardware Reference Guide...
  • Page 73: A Vsp G200 Storage System Components

    VSP G200 storage system components The VSP G200 includes essential building blocks such as controllers, drive trays, and other optional front and back end components. Model lists □ Drive tray model lists □ Cable model list □ Battery specifications □...
  • Page 74: Model Lists

    Model lists Hitachi Virtual Storage Platform G200 controller model list CBSS controller components Part number Part name Quantity DW800-CBSS 2U chassis AC power supply unit Power cable (0.9 m) Power cable (2.5 m) Backup module (BKM) Front bezel (2U) Binder...
  • Page 75 1 k byte =1,024 bytes, which are actually displayed on PCs that you are using. The parity group capacity values displayed in the storage management software are calculated as 1 k byte =1,024 bytes. VSP G200 storage system components Hitachi Virtual Storage Platform G200 Hardware Reference Guide...
  • Page 76 200 GB, 2.5-inch, MLC, 12- 0-24 Gbps, SSD DKC-F810I-300KCM 300 GB, 2.5-inch, 15k, 6-Gbps, 0-24 SAS, HDD (contains BNST) DKC-F810I-300KCMC 300 GB, 2.5-inch,15k, 6-Gbps, 0-24 SAS, HDD VSP G200 storage system components Hitachi Virtual Storage Platform G200 Hardware Reference Guide...
  • Page 77 1 k byte =1,024 bytes, which are actually displayed on PCs that you are using. The parity group capacity values displayed in the storage management software are calculated as 1 k byte =1,024 bytes. VSP G200 storage system components Hitachi Virtual Storage Platform G200 Hardware Reference Guide...
  • Page 78 0-12 (contains BNST) DKC-F810I-1R2J5MC 1.2 TB, SAS, LFF HDD 0-12 DKC-F810I-1R8J61 1.8 TB, 3.5-inch, 10k, SAS, 0-12 DKC-F810I-4R0H3M 4 TB, 7.2K 3.5-inch, SAS, HDD 0-12 (contains BNST) VSP G200 storage system components Hitachi Virtual Storage Platform G200 Hardware Reference Guide...
  • Page 79 Backup module Front bezel (2U) Binder Air filter SAS cable label Controller DW-F800-BM10 Cache flash memory CBSLD controller optional components Part number Part name Quantity DW-F800-CTLS Controller Board VSP G200 storage system components Hitachi Virtual Storage Platform G200 Hardware Reference Guide...
  • Page 80 1 k byte =1,024 bytes, which are actually displayed on PCs that you are using. The parity group capacity values displayed in the storage management software are calculated as 1 k byte =1,024 bytes. VSP G200 storage system components Hitachi Virtual Storage Platform G200 Hardware Reference Guide...
  • Page 81: Drive Tray Model Lists

    480 GB, MLC, 12-Gbps, SAS, 0-24 SFF, SSD DKC-F810I-960MGM 960 GB, MLC, 12-Gbps, SAS, 0-24 SFF, SSD DKC-F810I-600JCM 600 GB, 10kmin, 6-Gbps, SAS, 0-24 SFF, drive (contains BNST) VSP G200 storage system components Hitachi Virtual Storage Platform G200 Hardware Reference Guide...
  • Page 82 Power cable (1.5 m) Power cable (3 m) Front bezel (2U) Air filter Optional LFF drive tray components Model number Part name Quantity DKC-F810I-400M6M 400 GB, LFF, Flash drive 0-12 VSP G200 storage system components Hitachi Virtual Storage Platform G200 Hardware Reference Guide...
  • Page 83 The drive capacity values are calculated as 1 G byte =1,000,000,000 bytes. This definition is different from that calculated as 1 k byte =1,024 bytes, which are actually displayed on PCs that VSP G200 storage system components Hitachi Virtual Storage Platform G200 Hardware Reference Guide...
  • Page 84 The drive capacity values are calculated as 1 G byte =1,000,000,000 bytes. This definition is different from that calculated as 1 k byte =1,024 bytes, which are actually displayed on PCs that VSP G200 storage system components Hitachi Virtual Storage Platform G200 Hardware Reference Guide...
  • Page 85: Cable Model List

    Model number Specification A-6515-GM5L 5 m LC-LC optical cable for optical A-6515-GM10L 10 m LC-LC optical cable for optical A-6515-GM20L 20 m LC-LC optical cable for optical VSP G200 storage system components Hitachi Virtual Storage Platform G200 Hardware Reference Guide...
  • Page 86: Battery Specifications

    Up to 75.2º F (24º C) 5 years 5 years Up to 86º F (30º C) 5 years 4 years Up to 93.2º (34º C) 4 years 3 years VSP G200 storage system components Hitachi Virtual Storage Platform G200 Hardware Reference Guide...
  • Page 87: Raid Specifications

    6D+2P, 12D+2P, 14D+2P Note: Although certain RAID configurations support redundancy in the event of a drive failure, best practices dictate that you back up data on a regular basis. VSP G200 storage system components Hitachi Virtual Storage Platform G200 Hardware Reference Guide...
  • Page 88 VSP G200 storage system components Hitachi Virtual Storage Platform G200 Hardware Reference Guide...
  • Page 89: B Vsp G200 Storage System Specifications

    (NF/14 TB) 1,351 TB Maximum external configuration 8 PB Memory Cache memory capacity 32 GB/64 GB Cache memory capacity with NAS module is installed Cache flash memory BM10 VSP G200 storage system specifications Hitachi Virtual Storage Platform G200 Hardware Reference Guide...
  • Page 90 DBS/DBSC/DBL/ 55dB DBLC/DBF DBSD/DBLD 55dB (*5 *6) DB60/DB60C 71dB Non-stop Control PCB Supported maintenance Cache memory Supported Cache flash memory Supported Power supply, fan Supported Microcode Supported VSP G200 storage system specifications Hitachi Virtual Storage Platform G200 Hardware Reference Guide...
  • Page 91 *8: The capacity of the cache memory installed in RAID controller. A cache memory installed in NAS module is not included. *9: When NAS Module is installed, the Diskless configuration is not supported. VSP G200 storage system specifications Hitachi Virtual Storage Platform G200 Hardware Reference Guide...
  • Page 92 VSP G200 storage system specifications Hitachi Virtual Storage Platform G200 Hardware Reference Guide...
  • Page 93: C Vsp G200 Storage System Mechanical Specifications

    VSP G200 storage system mechanical specifications The storage system mechanical specifications are described for VSP G200 . VSP G200 mechanical specifications (AC power supply model) □ VSP G200 mechanical specifications (DC power supply model) □ VSP G200 storage system mechanical specifications...
  • Page 94: Vsp G200 Mechanical Specifications (Ac Power Supply Model)

    2.5-inch drives, 3.5-inch drives, and flash drives. The chassis consists of an ENC and AC-DC power supplies equipped with built-in cooling fans. VSP G200 storage system mechanical specifications Hitachi Virtual Storage Platform G200 Hardware Reference Guide...
  • Page 95 Maximum number of drives that 24 drives CBSS can be mounted 12 drives CBSL SFF drive tray 24 drives LFF drive tray 12 drives FMD drive tray 12 drives VSP G200 storage system mechanical specifications Hitachi Virtual Storage Platform G200 Hardware Reference Guide...
  • Page 96 Up to 86º F (30º C) 5 years 4 years Up to 93.2º (34º C) 4 years 3 years Up to 104º (40º C) 3 years 2 years VSP G200 storage system mechanical specifications Hitachi Virtual Storage Platform G200 Hardware Reference Guide...
  • Page 97 WxDxH: 19 x 32 x 3.5 inches (483 x 813 x 88 mm) SFF drive tray WxDxH: 19 x 22.2 x 3.5 inches (483 x 565 x 88.2 mm) VSP G200 storage system mechanical specifications Hitachi Virtual Storage Platform G200 Hardware Reference Guide...
  • Page 98 When the storage system enters Cache Backup mode, the amber WARNING LED goes on to when the system starts. This warning indicates that the VSP G200 storage system mechanical specifications Hitachi Virtual Storage Platform G200 Hardware Reference Guide...
  • Page 99: Vsp G200 Mechanical Specifications (Dc Power Supply Model)

    Drive trays Quantity Component Description A drive tray that supports 2.5- SFF drive tray (DBSD) inch disk drives and 2.5-inch flash drives. The drive tray VSP G200 storage system mechanical specifications Hitachi Virtual Storage Platform G200 Hardware Reference Guide...
  • Page 100: Drive Specifications

    3.5-type: 5874.22 GB, 7,200 3.5-type: 9790.36 GB, 7,200 Maximum number of drives that 24 drives CBSSD, SFF drive tray can be mounted 12 drives CBSLD, LFF drive tray VSP G200 storage system mechanical specifications Hitachi Virtual Storage Platform G200 Hardware Reference Guide...
  • Page 101 512 bytes Maximum number of hosts using a Fibre Channel switch Maximum number of hosts using a network switch RAID specifications D: Data drive, P: Parity drive. VSP G200 storage system mechanical specifications Hitachi Virtual Storage Platform G200 Hardware Reference Guide...
  • Page 102 WxDxH: 19 x 22.2 x 3.5 inches (483 x 565 x 88.2 mm) LFF drive tray WxDxH: 19 x 22.2 x 3.5 inches (483 x 565 x 88.2 mm) VSP G200 storage system mechanical specifications Hitachi Virtual Storage Platform G200 Hardware Reference Guide...
  • Page 103 The warning indication disappears within six hours. Even when the warning is shown, normal operation is assured in Write-Through. Read and write performance is lowered because the Write Cache function is disabled. VSP G200 storage system mechanical specifications Hitachi Virtual Storage Platform G200 Hardware Reference Guide...
  • Page 104 3 hours every six months. Insulation performance Item Specifications Insulation withstand voltage AC 1,500 V (100 mA, 1 min) Insulation resistance DC 500 V, 10 M Ω or more VSP G200 storage system mechanical specifications Hitachi Virtual Storage Platform G200 Hardware Reference Guide...
  • Page 105: D Electrical Specifications For Vsp G200

    Electrical specifications for VSP G200 The electrical specifications are described for the storage system. Electrical specifications □ VSP G200 electrical specifications (DC power supply) □ Electrical specifications for VSP G200 Hitachi Virtual Storage Platform G200 Hardware Reference Guide...
  • Page 106: Electrical Specifications

    This table shows the power requirement (100 V or 200 V) for the maximum configuration . The actual required power might exceed the value shown in the table when the tolerance is included. Electrical specifications for VSP G200 Hitachi Virtual Storage Platform G200 Hardware Reference Guide...
  • Page 107: Vsp G200 Electrical Specifications (Dc Power Supply)

    Connector: Positronic Industries Inc., PCS Series Heat value 1800 1550 1120 (kJ/h) Steady-state power (W) Power consumption Input current 15.9 15.9 No connection Remote adapter No connection Electrical specifications for VSP G200 Hitachi Virtual Storage Platform G200 Hardware Reference Guide...
  • Page 108 Electrical specifications for VSP G200 Hitachi Virtual Storage Platform G200 Hardware Reference Guide...
  • Page 109: E Environmental Specifications For Vsp G200

    Environmental specifications for VSP G200 The environmental specifications are described for the storage system. Environmental specifications □ VSP G200 environmental specifications (DC power supply) □ Environmental specifications for VSP G200 Hitachi Virtual Storage Platform G200 Hardware Reference Guide...
  • Page 110: Environmental Specifications

    Transport, storage -22°F to 140°F -22°F to 122°F (-30°C to 50°C) (-30°C to 60°C) Temperature 10 or less change rate (°C/h) Humidity State Percentage Operating 8 to 80 Environmental specifications for VSP G200 Hitachi Virtual Storage Platform G200 Hardware Reference Guide...
  • Page 111 900 (Environmental temperature: 10°C to 35°C) when DKC-F710I-1R6FM or DKC-F710I-3R2FM drive is installed. (Environmental temperature: 10°C to 40°C) 3,000 3,000 (Environmental temperature: 10°C to 32°C) Operating (m) (Environmental temperature: 10°C to 32°C) Environmental specifications for VSP G200 Hitachi Virtual Storage Platform G200 Hardware Reference Guide...
  • Page 112: Acoustic Noise

    7.2 B to 8.1 B, according to the ambient temperature, drive configuration, and operating status. When accessing the dense intermix drive tray, do not work for long times at the rear of the rack. Environmental specifications for VSP G200 Hitachi Virtual Storage Platform G200 Hardware Reference Guide...
  • Page 113: Vsp G200 Environmental Specifications (Dc Power Supply)

    Non-operating (m/s2) 5.0 or less (5 to 300 Hz): No critical damage for product. 9.8 (1.0 G) Adopt fall- prevention safety measures. Transport (packed) 5.0 or less (m/s2) Environmental specifications for VSP G200 Hitachi Virtual Storage Platform G200 Hardware Reference Guide...
  • Page 114 Therefore, this standard value might be exceeded if the maximum load continues under high- temperature environment or if a system failure occurs. Standby 55 dB Environmental specifications for VSP G200 Hitachi Virtual Storage Platform G200 Hardware Reference Guide...
  • Page 115: F Iscsi Standards And Specifications

    The following tables describe the standards and specifications for using iSCSI in a hosting environment. iSCSI standards □ iSCSI specifications □ iSCSI standards and specifications Hitachi Virtual Storage Platform G200 Hardware Reference Guide...
  • Page 116: Iscsi Standards

    Path failover HDLM Supports Microsoft MPIO (Multi Path I/O) Link 10 Gbps SFP+ Transfer speed 10 Gbps Connector type Cable Optical OM3, OM2 MMF cable iSCSI standards and specifications Hitachi Virtual Storage Platform G200 Hardware Reference Guide...
  • Page 117 Changeable among 1 to 65,535. Observe the following if changing values: • The setting of the corresponding host should also be changed to log in the new port number. iSCSI standards and specifications Hitachi Virtual Storage Platform G200 Hardware Reference Guide...
  • Page 118 Qualified Name. The iqn consists of a type identifier, "iqn," a date of domain acquisition, a domain name, and a character string given by the individual who acquired the domain. Example: iqn.1994-04.jp.co.hitachi:rsd.d7m.t.10020.1b000.tar iSCSI standards and specifications Hitachi Virtual Storage Platform G200 Hardware Reference Guide...
  • Page 119 Item Specification Comments eui: 64-bit Extended Unique Identifier. The eui consists of a type identifier, "eui," and an ASCII-coded, hexadecimal, EUI-64 identifier. Example: eui.0123456789abcdef iSCSI standards and specifications Hitachi Virtual Storage Platform G200 Hardware Reference Guide...
  • Page 120 Hitachi Virtual Storage Platform G200 Hardware Reference Guide...
  • Page 121: G Replacement Parts

    Replacement parts Part replacement is essential for maintaining the high performance of the system. Replacing system components is covered by the maintenance service contract. Battery unit □ Replacement parts Hitachi Virtual Storage Platform G200 Hardware Reference Guide...
  • Page 122: Battery Unit

    If not, the battery might reach its lifespan earlier than expected and become unusable within three years. When replacing the battery, follow the given procedure for disposing a used battery. Replacement parts Hitachi Virtual Storage Platform G200 Hardware Reference Guide...
  • Page 123: Regulatory Compliance

    EN5524: 2010 EN61000-3.2:2006+A1 EN61000-3.3:2008 Safety certifications UL and CSA cTUVus USA and Canada 60950-1:2007 EN60950-1:2006+A1 Germany IEC60950-1:2005+A1 All CB countries IEC60950-1:2005+A1 S-Mark Argentina TP TC 004/2011 Russia CNS 14336-1 BSMI Taiwan Regulatory compliance Hitachi Virtual Storage Platform G200 Hardware Reference Guide...
  • Page 124 Specification Country regulation logo EN60950-1:2006+A1 Radio interference VCCI V-3/2013.04 VCCI Japan voluntary control Table 4 Cryptography Standards and Certifications for VSP G200 Standard Certification Country regulation Description Federal Information #2694 FIPS 140-2 USA and Canada Encryption back end Processing Standards...
  • Page 125 85 small form-factor 46 cables removing 71 CBSL controller 30 AC power supply unit 29, 34 CBSL controller 30 electric shock 12 front panel bezel 30 electrical 105 rear panel 32 Index Hitachi Virtual Storage Platform G200 Hardware Reference Guide...
  • Page 126 LAN blade LEDs and connectors 42 CBSS controller 28 large form factor drive tray dense intermix drive tray 56 AC power supply unit 57 flash module drive tray 53 DC power supply units 57 Index Hitachi Virtual Storage Platform G200 Hardware Reference Guide...
  • Page 127 70 storage system controllers CBSL 30 CBSS 26 storage system specifications 89 storing the storage system 70 supported configurations 20 SVP 65 hardware specifications 68 Virtual Storage Platform G200 25 Index Hitachi Virtual Storage Platform G200 Hardware Reference Guide...
  • Page 128 Index Hitachi Virtual Storage Platform G200 Hardware Reference Guide...
  • Page 129 Hitachi Virtual Storage Platform G200 Hardware Reference Guide...
  • Page 130 Hitachi Data Systems Corporate Headquarters 2845 Lafayette Street Santa Clara, California 95050-2639 U.S.A. www.hds.com Regional Contact Information Americas +1 408 970 1000 info@hds.com Europe, Middle East, and Africa +44 (0) 1753 618000 info.emea@hds.com Asia Pacific +852 3189 7900 hds.marketing.apac@hds.com Contact Us www.hds.com/en-us/contact.html...

Table of Contents