Procedure
1.
2.
3.
4.
5.

Checking cache flash memory screws

Procedure
1.
2.
3.
4.
256
In the Replace Cache Flash Memory window, click Restore.
A progress bar shows the replacement status.
When the progress bar goes away and the completion message appears,
clickClose.
Click the CFMs tab in the Controller Chassis window.
Verify that the status of the new CFM is Normal.
If necessary, click Refresh at the top-right of the window to update the
status of the window.
Log out and close the Maintenance Utility window.
In the Alert Detail window of the maintenance utility, click Close.
In the left pane, click Controller Chassis.
Click the CFM tab of the maintenance utility to check the location of the
target CFM.
Click the target CFM, and then click Replace.
Maintenance Utility window for CBSS or CBSL
Maintenance Utility window for CBLM or CBLH
Replacing cache flash memory
Service Guide for VSP Gx00 and VSP Fx00 Models