Hitachi Virtual Storage Platform G400 Reference Manual

Hitachi Virtual Storage Platform G400 Reference Manual

Hide thumbs Also See for Virtual Storage Platform G400:
Table of Contents

Advertisement

Hitachi Virtual Storage Platform G400,
G600
Hardware Reference Guide
MK-94HM8022-08
May 2017

Advertisement

Table of Contents
loading

Summary of Contents for Hitachi Virtual Storage Platform G400

  • Page 1 Hitachi Virtual Storage Platform G400, G600 Hardware Reference Guide MK-94HM8022-08 May 2017...
  • Page 2 Materials. “Materials” mean text, data, photographs, graphics, audio, video and documents. Hitachi reserves the right to make changes to this Material at any time without notice and assumes no responsibility for its use. The Materials contain the most current information available at the time of publication.
  • Page 3: Table Of Contents

    Document conventions................... 13 Conventions for storage capacity values..............14 Accessing product documentation................15 Getting help......................15 Comments......................16 1 Hitachi Virtual Storage Platform G400, G600 hardware overview..... 17 Block configuration....................19 Unified configuration....................19 VSP G400 model....................19 VSP G600 model....................21 Features........................ 22 Scalability......................
  • Page 4 PCIe cable connector....................57 Host port expansion chassis power supply............... 59 6 VSP service processor server..............61 Service processor description.................. 62 SVP front panel......................62 SVP rear panel....................... 63 Service processor hardware specifications..............64 Hitachi Virtual Storage Platform G400, G600 Hardware Reference Guide...
  • Page 5 E Environmental specifications for VSP G400, G600........93 Environmental specifications................... 94 F iSCSI standards and specifications............99 iSCSI standards....................100 iSCSI specifications....................100 G Replacement parts................105 Battery unit......................106 H Regulatory compliance............... 107 Index....................109 Hitachi Virtual Storage Platform G400, G600 Hardware Reference Guide...
  • Page 6 Hitachi Virtual Storage Platform G400, G600 Hardware Reference Guide...
  • Page 7: Preface

    □ Product version □ Release notes □ Changes in this revision □ Document conventions □ Conventions for storage capacity values □ Accessing product documentation □ Getting help □ Comments □ Preface Hitachi Virtual Storage Platform G400, G600 Hardware Reference Guide...
  • Page 8: Safety And Environmental Notices

    Backup Hitachi cannot guarantee against data loss due to failures. Therefore, back up your data to minimize chances for data loss. Data backup is also critical when hardware components are added or replaced, because performing such hardware procedures restores parameter settings that can affect how data is managed on the storage systems.
  • Page 9: General Safety Guidelines

    DAMAGE. Notes on use When using the Hitachi storage system, be sure to read this guide and understand the operating procedures and instructions described herein thoroughly before staring your operation. The array complies with FDA radiation performance standard 21 CFR subchapter J.
  • Page 10: Handling Of Heavy Parts

    • Do not supply power to any device with rotating or moving parts that are not properly covered. • Tuck in your tie, scarf, shirt, or any other loose clothing to prevent it from getting caught by a rotating or moving part. Preface Hitachi Virtual Storage Platform G400, G600 Hardware Reference Guide...
  • Page 11: Preventing Machine Damage

    • Keep these vents open and verify they are not blocked to keep the storage system ventilated. Cool air enters the storage system from the air vent on the front panel and exits through the vent on the rear panel. Preface Hitachi Virtual Storage Platform G400, G600 Hardware Reference Guide...
  • Page 12: Emergency Procedures

    • If the fire continues to burn after the power is turned off, take necessary actions such as using a fire extinguisher or contacting the fire department. Intended audience This document is intended for Hitachi Data Systems representatives and authorized service providers who install, configure, or operate storage systems.
  • Page 13: Product Version

    Product version This document revision applies to the following product versions: • VSP G400, G600 firmware 83-04-4x or later • Hitachi Storage Virtualization Operating System (SVOS) 7.2 or later • Hitachi NAS firmware version 13.1 or later Release notes Read the release notes before installing and using this product. They may contain requirements or restrictions that are not fully described in this document or updates or corrections to this document.
  • Page 14: Conventions For Storage Capacity Values

    1 kilobyte (KB) 1,000 (10 ) bytes 1 megabyte (MB) 1,000 KB or 1,000 bytes 1 gigabyte (GB) 1,000 MB or 1,000 bytes 1 terabyte (TB) 1,000 GB or 1,000 bytes Preface Hitachi Virtual Storage Platform G400, G600 Hardware Reference Guide...
  • Page 15: Accessing Product Documentation

    Getting help Hitachi Data Systems Support Connect is the destination for technical support of products and solutions sold by Hitachi Data Systems. To contact technical support, log on to Hitachi Data Systems Support Connect for contact information: https://support.hds.com/en_us/contact-us.html. Hitachi Data Systems Community...
  • Page 16: Comments

    Please send us your comments on this document to doc.comments@hds.com. Include the document title and number, including the revision level (for example, -07), and refer to specific sections and paragraphs whenever possible. All comments become the property of Hitachi Data Systems Corporation. Thank you!
  • Page 17: Hitachi Virtual Storage Platform G400, G600 Hardware Overview

    Hitachi Virtual Storage Platform G400, G600 hardware overview Hitachi Virtual Storage Platform G400, G600 are modular, rack-mountable, storage systems. The storage systems contain dual controllers for communicating with a data host. Each controller contains its own processor, dual in-line cache memory modules (DIMMs), cache flash memory (CFM), battery, and fans.
  • Page 18 Features □ Scalability □ Hitachi Virtual Storage Platform G400, G600 hardware overview Hitachi Virtual Storage Platform G400, G600 Hardware Reference Guide...
  • Page 19: Block Configuration

    • 16-Gbps Fibre Channel (2-port): 28 ports per system (or 32 ports per systems for systems without drives or 12 ports per systems when NAS Modules are installed) Hitachi Virtual Storage Platform G400, G600 hardware overview Hitachi Virtual Storage Platform G400, G600 Hardware Reference Guide...
  • Page 20 4U (174.3 mm) DB60 (power drive tray supply, contains BNST) • DW-F800- DB60C Related references • Examples of supported VSP G400 configurations on page 23 Hitachi Virtual Storage Platform G400, G600 hardware overview Hitachi Virtual Storage Platform G400, G600 Hardware Reference Guide...
  • Page 21: Vsp G600 Model

    CBLM DW800-CBL DW-F800-CTLM 4U (174.3 mm) Controller Model number Description DW-F800-NAS Optional component for file storage configuration. NAS modules only provide file support. Hitachi Virtual Storage Platform G400, G600 hardware overview Hitachi Virtual Storage Platform G400, G600 Hardware Reference Guide...
  • Page 22: Features

    2,048 Maximum number of DP pool volumes 4,096 Maximum number of DP pools Maximum number of iSCSI hosts connected through a network switch Hitachi Virtual Storage Platform G400, G600 hardware overview Hitachi Virtual Storage Platform G400, G600 Hardware Reference Guide...
  • Page 23: Scalability

    Note: If a drive is inserted into a slot of a dense intermix drive tray when the installed number of drives exceeds 240 slots per path, the drive is blocked. Related references • VSP G600 model on page 21 Hitachi Virtual Storage Platform G400, G600 hardware overview Hitachi Virtual Storage Platform G400, G600 Hardware Reference Guide...
  • Page 24: Maximum Number Of Mounted Drive Trays

    SFF drive + LFF drive + Dense intermix SFF, LFF drives dense intermix dense intermix drive tray drive tray drive tray CBLM Hitachi Virtual Storage Platform G400, G600 hardware overview Hitachi Virtual Storage Platform G400, G600 Hardware Reference Guide...
  • Page 25 SFF drive + LFF drive + Dense intermix SFF, LFF drives dense intermix dense intermix drive tray drive tray drive tray CBLM Hitachi Virtual Storage Platform G400, G600 hardware overview Hitachi Virtual Storage Platform G400, G600 Hardware Reference Guide...
  • Page 26 Hitachi Virtual Storage Platform G400, G600 hardware overview Hitachi Virtual Storage Platform G400, G600 Hardware Reference Guide...
  • Page 27: Virtual Storage Platform G400, G600 Controller

    Virtual Storage Platform G400, G600 controller The Virtual Storage Platform G400, G600 models are equipped with dual controllers for communicating with a data host. Each controller contains its own processor, dual in-line cache memory modules (DIMMs), cache flash memory (CFM), battery, and fans. The controller has an Ethernet connection for out-of-band management using Hitachi Device Manager - Storage Navigator.
  • Page 28: Cblm Controller

    (SIM) are issued: 452xxx, 462xxx, 3077xx, 4100xx, and 410100. LED might turn off during user maintenance. ALARM LED Off: Normal operation. Virtual Storage Platform G400, G600 controller Hitachi Virtual Storage Platform G400, G600 Hardware Reference Guide...
  • Page 29: Cblm Front Panel Without Bezel

    (SIM) are issued: 452xxx, 462xxx, 3077xx, 4100xx, and 410100. Controller 1 (bottom) and Controllers Controller 2 (top). Virtual Storage Platform G400, G600 controller Hitachi Virtual Storage Platform G400, G600 Hardware Reference Guide...
  • Page 30: Cblm Rear Panel

    (for example, BKMF-10 and BKMF-20). CBLM rear panel The following table describes the definitions of the CBLM controller rear panel LEDs. Virtual Storage Platform G400, G600 controller Hitachi Virtual Storage Platform G400, G600 Hardware Reference Guide...
  • Page 31 Number Item Power supply unit Front end module Back end module LAN blade Rear view (includes NAS modules) Virtual Storage Platform G400, G600 controller Hitachi Virtual Storage Platform G400, G600 Hardware Reference Guide...
  • Page 32: Cblm Power Supply Unit Leds And Connectors

    ALM/RDY LED Red: Power supply unit can be replaced. Receptacle Connects to the power cable provided with the storage system. RDY LED Green: Normal operation. Virtual Storage Platform G400, G600 controller Hitachi Virtual Storage Platform G400, G600 Hardware Reference Guide...
  • Page 33: Host, Network, And Drive Tray Ports And Leds

    LEDs display the operating status of the storage system. Front end module descriptions □ LAN blade LEDs and connectors □ Back end module LEDs and connectors □ Host, Network, and Drive Tray Ports and LEDs Hitachi Virtual Storage Platform G400, G600 Hardware Reference Guide...
  • Page 34: Front End Module Descriptions

    Blink blue: Front end module is in communication status. iSCSI connectors Connect to Ethernet LAN cables. 10-Gbps iSCSI board LEDs and connectors (copper) Host, Network, and Drive Tray Ports and LEDs Hitachi Virtual Storage Platform G400, G600 Hardware Reference Guide...
  • Page 35: 8-Gbps, 16-Gbps, Or 32-Gbps Fibre Channel (4-Port) Board Leds And Connectors

    Off: No link connection or not ready to communicate. iSCSI connectors Connect to Ethernet LAN cables. 8-Gbps, 16-Gbps, or 32-Gbps Fibre Channel (4-port) board LEDs and connectors Host, Network, and Drive Tray Ports and LEDs Hitachi Virtual Storage Platform G400, G600 Hardware Reference Guide...
  • Page 36 Red: Small form factor pluggable can be removed. Blue: Normal link status at 16- Gbps (16-Gbps). Blue: Normal link status at 32- Gbps (32-Gbps). Host, Network, and Drive Tray Ports and LEDs Hitachi Virtual Storage Platform G400, G600 Hardware Reference Guide...
  • Page 37: 16-Gbps Fibre Channel (2-Port) Board Leds And Connectors

    CHB-1B CHB-1C CHB-1D CHB-1E CHB-1F CHB-1G CHB-1H CHB-2A CHB-2B CHB-2C CHB-2D CHB-2E CHB-2F CHB-2G CHB-2H 16-Gbps Fibre Channel (2-port) board LEDs and connectors Host, Network, and Drive Tray Ports and LEDs Hitachi Virtual Storage Platform G400, G600 Hardware Reference Guide...
  • Page 38: Lan Blade Leds And Connectors

    Port 2 CHB-1A CHB-1B CHB-1C CHB-1D CHB-1E CHB-1F CHB-1G CHB-1H CHB-2A CHB-2B CHB-2C CHB-2D CHB-2E CHB-2F CHB-2G CHB-2H LAN blade LEDs and connectors Host, Network, and Drive Tray Ports and LEDs Hitachi Virtual Storage Platform G400, G600 Hardware Reference Guide...
  • Page 39: Back End Module Leds And Connectors

    Uninterruptible power supply (UPS) port Back end module LEDs and connectors The back end module LEDs display the operating status of the module. Host, Network, and Drive Tray Ports and LEDs Hitachi Virtual Storage Platform G400, G600 Hardware Reference Guide...
  • Page 40 Port LED Blue: Link status is normal. PATH 0 connector Connect to a drive tray. PATH 1 connector Connects to a drive tray. Host, Network, and Drive Tray Ports and LEDs Hitachi Virtual Storage Platform G400, G600 Hardware Reference Guide...
  • Page 41: Storage System Drive Trays

    Large form-factor (LFF) drive tray □ Flash module drive (FMD) tray □ Dense intermix drive tray □ SFF and LFF AC power supply unit LEDs and connectors □ Storage system drive trays Hitachi Virtual Storage Platform G400, G600 Hardware Reference Guide...
  • Page 42: Small Form-Factor (Sff) Drive Tray

    Can be turned on or turned off by the maintenance utility. Lock Locks and unlocks the front panel bezel by using the supplied key. SFF front panel without bezel Storage system drive trays Hitachi Virtual Storage Platform G400, G600 Hardware Reference Guide...
  • Page 43: Sff Rear Panel

    Small form factor drives The twenty-four 2.5-inch small form factor drives are positioned vertically. The slots are organized from 0 to 23. SFF rear panel Storage system drive trays Hitachi Virtual Storage Platform G400, G600 Hardware Reference Guide...
  • Page 44: Large Form-Factor (Lff) Drive Tray

    Green: Normal operation. ALM LED Red: Power supply unit can be replaced. RDY LED Green: Normal operation. Large form-factor (LFF) drive tray LFF with front panel bezel Storage system drive trays Hitachi Virtual Storage Platform G400, G600 Hardware Reference Guide...
  • Page 45: Lff Front Panel Without Bezel

    LFF front panel without bezel Number Item Description POWER, READY, and LOCATE LEDs Green: Drive tray is powered Green: Drive tray is operational. Amber: Storage system drive trays Hitachi Virtual Storage Platform G400, G600 Hardware Reference Guide...
  • Page 46: Lff Rear Panel

    Can be turned on or turned off by the maintenance utility. ALARM LED Red: ENC can be replaced. PATH (IN) LED Blue: IN side port is linked up. Storage system drive trays Hitachi Virtual Storage Platform G400, G600 Hardware Reference Guide...
  • Page 47: Flash Module Drive (Fmd) Tray

    Green: Drive tray is operational. LOCATE LED Amber: • Indicates the location of the chassis. • Can be turned on or turned off by the maintenance utility. Storage system drive trays Hitachi Virtual Storage Platform G400, G600 Hardware Reference Guide...
  • Page 48: Fmd Front Panel Without Bezel

    If the storage system is turned on, the LED stops blinking when the capacitor is finished charging (approximately two minutes). Note: ACT indicator is only printed on some types of FMDs. Storage system drive trays Hitachi Virtual Storage Platform G400, G600 Hardware Reference Guide...
  • Page 49: Fmd Rear Panel

    6, 7, 8 3, 4, 5 0, 1, 2 FMD rear panel Number Item Description POWER LED Green: ENC is in the power-on state. LOCATE LED Amber: Storage system drive trays Hitachi Virtual Storage Platform G400, G600 Hardware Reference Guide...
  • Page 50: Dense Intermix Drive Tray

    AC IN LED operating normally. ALM REPLACE LED Red: Power supply unit can be replaced. Dense intermix drive tray Dense intermix drive tray with front panel bezel Storage system drive trays Hitachi Virtual Storage Platform G400, G600 Hardware Reference Guide...
  • Page 51: Dense Intermix Drive Tray Display Leds

    Dense intermix drive tray display LEDs Number Item Description Green: Normal operation. Blink green: Drive is being accessed. ALM LED Red: Drive stopped due to a failure and can be replaced. Storage system drive trays Hitachi Virtual Storage Platform G400, G600 Hardware Reference Guide...
  • Page 52: Dense Intermix Drive Tray Rear Panel

    PATH (OUT) connector Connect to a drive tray. PATH (IN) LED Blue: IN side port is linked up. PATH (IN) connector Connects to a controller or drive tray. Storage system drive trays Hitachi Virtual Storage Platform G400, G600 Hardware Reference Guide...
  • Page 53: Sff And Lff Ac Power Supply Unit Leds And Connectors

    AC power supply units include LEDs to display its operating status. Number Item Description Green: Normal operation. RDY LED AC IN LED Green: AC input is operating normally. Red: Power supply unit can be ALM LED replaced. Storage system drive trays Hitachi Virtual Storage Platform G400, G600 Hardware Reference Guide...
  • Page 54 Storage system drive trays Hitachi Virtual Storage Platform G400, G600 Hardware Reference Guide...
  • Page 55: Host Port Expansion Chassis

    Host port expansion chassis front panel bezel LEDs □ PCIe switchboard □ Host port expansion chassis fan □ PCIe cable connector □ Host port expansion chassis power supply □ Host port expansion chassis Hitachi Virtual Storage Platform G400, G600 Hardware Reference Guide...
  • Page 56: Host Port Expansion Chassis Front Panel Bezel Leds

    Green: Host port expansion is POWER LED turned on. Amber: PCIe module is turned Off: PCIe module is turned off. Lock or unlock the front bezel. Safety lock PCIe switchboard Host port expansion chassis Hitachi Virtual Storage Platform G400, G600 Hardware Reference Guide...
  • Page 57: Host Port Expansion Chassis Fan

    Off: PCIe switchboard is powered off. Host port expansion chassis fan Number Item Description ALM LED Red: Fan failure has occurred. Off: Normal operation. PCIe cable connector Host port expansion chassis Hitachi Virtual Storage Platform G400, G600 Hardware Reference Guide...
  • Page 58 Off: Basic PCIe is normal or not set. Link Option LED Green: Option PCIe Gen-3.0 (8- Gbps) is linked up normally. Off: Option PCIe is not linked up (PCIe cable might not be Host port expansion chassis Hitachi Virtual Storage Platform G400, G600 Hardware Reference Guide...
  • Page 59: Host Port Expansion Chassis Power Supply

    Number Item Description ALM/RDY LED Red: Host port expansion chassis power supply can be replaced safely. Green: Normal operation. AC IN LED Blue: AC input is normal. Host port expansion chassis Hitachi Virtual Storage Platform G400, G600 Hardware Reference Guide...
  • Page 60 Host port expansion chassis Hitachi Virtual Storage Platform G400, G600 Hardware Reference Guide...
  • Page 61: Vsp Service Processor Server

    The SVP is available as: • A physical 1U management server provided by Hitachi Data Systems that runs Windows Embedded Standard 7. • A software application that runs Windows 7 Professional x64 Service Pack 1 (64-bit) on a customer-supplied server hardware, a VMware ESXi host, or Linux KVM host.
  • Page 62: Service Processor Description

    • Turning on automatic Windows updates or using the manual Windows update method. • Installing antivirus software that has been tested and approved by Hitachi. SVP front panel The front panel of the physical SVP is equipped with LEDs, a reset button, and a power button.
  • Page 63: Svp Rear Panel

    LAN ports. Number Description Power socket. Attach the power cable supplied with the SVP. Four LAN ports arranged as follows: LAN3 LAN4 LAN1 LAN2 VSP service processor server Hitachi Virtual Storage Platform G400, G600 Hardware Reference Guide...
  • Page 64: Service Processor Hardware Specifications

    2 TB Network interface card x4 ports (on-board NIC) + x1 IPMI (BMC) port Fans 2 x 4-cm 4-pin PWM fans Operating system Windows Embedded Standard 7 VSP service processor server Hitachi Virtual Storage Platform G400, G600 Hardware Reference Guide...
  • Page 65: Maintaining The Storage System

    For more complex maintenance activities, contact customer support. Storing the storage system □ Using flash module drives □ Powering off the storage system □ Removing cables □ Maintaining the storage system Hitachi Virtual Storage Platform G400, G600 Hardware Reference Guide...
  • Page 66: Storing The Storage System

    Follow the guidelines to avoid damaging the components when handling FMDs. • Check the main edge connector of the drive for any damage, deformation, dust, or debris before installing. Maintaining the storage system Hitachi Virtual Storage Platform G400, G600 Hardware Reference Guide...
  • Page 67: Powering Off The Storage System

    Observe the following instructions when removing cables form the storage system. To remove a SAS cable, pull the tab of the SAS cable (1) to release the latch and remove the SAS cable (2). Maintaining the storage system Hitachi Virtual Storage Platform G400, G600 Hardware Reference Guide...
  • Page 68 (1) to release the latch and remove the SAS cable (2). To remove a LAN cable, push the top of the LAN cable connector (1) to release the latch and remove the LAN cable (2). Maintaining the storage system Hitachi Virtual Storage Platform G400, G600 Hardware Reference Guide...
  • Page 69: A Vsp G400, G600 Storage System Components

    Model lists □ Drive tray model lists □ Cable model list □ Battery specifications □ RAID specifications □ VSP G400, G600 storage system components Hitachi Virtual Storage Platform G400, G600 Hardware Reference Guide...
  • Page 70: Model Lists

    Front end module (16-Gbps 2- 2-16 port FC) DW-F800-4HF32R Front end module (32-Gbps, 2-16 16-Gbps 4-port FC) DW-F800-NAS NAS Module DW-F800-BS12G SAS Back end module VSP G400, G600 storage system components Hitachi Virtual Storage Platform G400, G600 Hardware Reference Guide...
  • Page 71: Drive Tray Model Lists

    960 GB, MLC, 12-Gbps, SAS, 0-24 SFF, SSD DKC-F810I-600JCM 600 GB, 10kmin, 6-Gbps, SAS, 0-24 SFF, drive (contains BNST) DKC-F810I-600JCMC 600 GB, 10kmin, 6-Gbps, SAS, 0-24 SFF, drive VSP G400, G600 storage system components Hitachi Virtual Storage Platform G400, G600 Hardware Reference Guide...
  • Page 72 4 TB, 7.2K, 6-Gbps, SAS, LFF, 0-12 drive DKC-F810I-6R0H9M 6 TB, 7.2K, 12-Gbps, SAS, LFF, 0-12 drive DKC-F810I-10RH9M 10 TB, 7.2K, 12-Gbps, SAS, 0-12 LFF, drive VSP G400, G600 storage system components Hitachi Virtual Storage Platform G400, G600 Hardware Reference Guide...
  • Page 73 1 k byte =1,024 bytes. Dense intermix drive tray components Model number Part name Quantity DW-F800-DB60 and DW-F800- 4U box DB60C Power supply unit VSP G400, G600 storage system components Hitachi Virtual Storage Platform G400, G600 Hardware Reference Guide...
  • Page 74: Cable Model List

    The parity group capacity values displayed in the storage management software are calculated as 1 k byte =1,024 bytes. Cable model list Numbers in parentheses show the quantities of the components. VSP G400, G600 storage system components Hitachi Virtual Storage Platform G400, G600 Hardware Reference Guide...
  • Page 75 10 m LC-LC optical cable for optical A-6515-GS20L 20 m LC-LC optical cable for optical A-6515-GS30L 30 m LC-LC optical cable for optical A-6515-GS50L 50 m LC-LC optical cable for optical VSP G400, G600 storage system components Hitachi Virtual Storage Platform G400, G600 Hardware Reference Guide...
  • Page 76: Battery Specifications

    Item setup) VSP G400, G600 models: SAS, SAS 7.2 krpm, RAID level flash drives mounted: 0, 1, 5, 6, 1+0 (DBW supports SAS 7.2k drives) VSP G400, G600 storage system components Hitachi Virtual Storage Platform G400, G600 Hardware Reference Guide...
  • Page 77 Note: Although certain RAID configurations support redundancy in the event of a drive failure, best practices dictate that you back up data on a regular basis. VSP G400, G600 storage system components Hitachi Virtual Storage Platform G400, G600 Hardware Reference Guide...
  • Page 78 VSP G400, G600 storage system components Hitachi Virtual Storage Platform G400, G600 Hardware Reference Guide...
  • Page 79: B Vsp G400, G600 Storage System Specifications

    TB) 996 TB TB) 664 TB (SSD/3.8 TB) (SSD/3.8 TB) 2,178 TB 1,452 TB (LFF HDD/10 (LFF HDD/10 TB) 7,049 TB TB) 4,699 TB VSP G400, G600 storage system specifications Hitachi Virtual Storage Platform G400, G600 Hardware Reference Guide...
  • Page 80 50Hz/60Hz : 200V to 240V DC input Acoustic level Operating 60dB CBSS/CBSL DBS/DBSC/DBL/ 60dB DBLC/DBF DBSD/DBLD (*5 *6) DB60/DB60C 71dB Standby 55dB CBSS/CBSL DBS/DBSC/DBL/ 55dB DBLC/DBF VSP G400, G600 storage system specifications Hitachi Virtual Storage Platform G400, G600 Hardware Reference Guide...
  • Page 81 *9: The capacity of the cache memory installed in RAID controller. A cache memory installed in NAS module is not included. *10: When NAS Module is installed, the Diskless configuration is not supported VSP G400, G600 storage system specifications Hitachi Virtual Storage Platform G400, G600 Hardware Reference Guide...
  • Page 82 VSP G400, G600 storage system specifications Hitachi Virtual Storage Platform G400, G600 Hardware Reference Guide...
  • Page 83: C Vsp G400, G600 Storage System Mechanical Specifications

    VSP G400, G600 storage system mechanical specifications The storage system mechanical specifications are described for VSP G400, G600 . VSP G400 and VSP G600 mechanical specifications □ VSP G400, G600 storage system mechanical specifications Hitachi Virtual Storage Platform G400, G600 Hardware Reference Guide...
  • Page 84: Vsp G400 And Vsp G600 Mechanical Specifications

    ENC and AC-DC power supplies equipped with built-in cooling fans. NAS module Component Description Optional component for block and file storage NAS module configuration VSP G400, G600 storage system mechanical specifications Hitachi Virtual Storage Platform G400, G600 Hardware Reference Guide...
  • Page 85 Maximum mountable quantity Mixing SFF, LFF, FMD, and dense intermix drive trays might affect the maximum number of drives that can be mounted. Component Specification VSP G400, G600 storage system mechanical specifications Hitachi Virtual Storage Platform G400, G600 Hardware Reference Guide...
  • Page 86: Host Interface

    10-Gbps copper iSCSI 8-Gbps Fibre Channel optical Number of ports (NAS Module not installed) 16-Gbps Fibre Channel optical (2-port) 16-Gbps Fibre Channel optical (4-port) VSP G400, G600 storage system mechanical specifications Hitachi Virtual Storage Platform G400, G600 Hardware Reference Guide...
  • Page 87 3 TB (or 4 TB when using the LDEVs of other storage systems) Maximum volumes/host groups and iSCSI 2048 targets Maximum number of volumes per RAID group 2048 VSP G400, G600 storage system mechanical specifications Hitachi Virtual Storage Platform G400, G600 Hardware Reference Guide...
  • Page 88 The table lists the values of a maximum configuration when all controllers and drives are mounted. Component Specification CBLM 187.39 pounds (85 kg) Approx 50.70 inches (23 kg) Approx 59.52 inches (27 kg) Approx. 83.77 pounds (38 kg) VSP G400, G600 storage system mechanical specifications Hitachi Virtual Storage Platform G400, G600 Hardware Reference Guide...
  • Page 89 Cache function disabled. When the battery is charged, the warning indication disappears, and the storage system continues the operation in the Write Cache function. VSP G400, G600 storage system mechanical specifications Hitachi Virtual Storage Platform G400, G600 Hardware Reference Guide...
  • Page 90 Insulation performance Item Specification Insulation withstand voltage AC 1,500 V (100 mA, 1 min) Insulation resistance DC 500 V, 10 M Ω or more VSP G400, G600 storage system mechanical specifications Hitachi Virtual Storage Platform G400, G600 Hardware Reference Guide...
  • Page 91: D Electrical Specifications For Vsp G400, G600

    Electrical specifications for VSP G400, G600 The electrical specifications are described for the storage systems. Electrical specifications □ Electrical specifications for VSP G400, G600 Hitachi Virtual Storage Platform G400, G600 Hardware Reference Guide...
  • Page 92: Electrical Specifications

    This table shows the power requirement (100 V or 200 V) for the maximum configuration . The actual required power might exceed the value shown in the table when the tolerance is included. Electrical specifications for VSP G400, G600 Hitachi Virtual Storage Platform G400, G600 Hardware Reference Guide...
  • Page 93: E Environmental Specifications For Vsp G400, G600

    Environmental specifications for VSP G400, G600 The environmental specifications are described for the storage systems. Environmental specifications □ Environmental specifications for VSP G400, G600 Hitachi Virtual Storage Platform G400, G600 Hardware Reference Guide...
  • Page 94: Environmental Specifications

    Transport, storage -22°F to 140°F -22°F to 122°F (-30°C to 50°C) (-30°C to 60°C) Temperature 10 or less change rate (°C/h) Humidity State Percentage Operating 8 to 80 Environmental specifications for VSP G400, G600 Hitachi Virtual Storage Platform G400, G600 Hardware Reference Guide...
  • Page 95 DKC-F710I-1R6FM or DKC-F710I-3R2FM drive is installed. (Environmental temperature: 10°C to 40°C) 3,000 3,000 (Environmental temperature: 10°C to 32°C) Operating (m) (Environmental temperature: 10°C to 32°C) Environmental specifications for VSP G400, G600 Hitachi Virtual Storage Platform G400, G600 Hardware Reference Guide...
  • Page 96: Acoustic Noise

    7.2 B to 8.1 B, according to the ambient temperature, drive configuration, and operating status. When accessing the dense intermix drive tray, do not work for long times at the rear of the rack. Environmental specifications for VSP G400, G600 Hitachi Virtual Storage Platform G400, G600 Hardware Reference Guide...
  • Page 97 Acoustic power level (LwA) measured by the ISO 7779 standard is 7.2 B. This value changes from 7.2 B to 8.1 B, according to the ambient temperature, drive configuration, and operating status. Environmental specifications for VSP G400, G600 Hitachi Virtual Storage Platform G400, G600 Hardware Reference Guide...
  • Page 98 Environmental specifications for VSP G400, G600 Hitachi Virtual Storage Platform G400, G600 Hardware Reference Guide...
  • Page 99: F Iscsi Standards And Specifications

    The following tables describe the standards and specifications for using iSCSI in a hosting environment. iSCSI standards □ iSCSI specifications □ iSCSI standards and specifications Hitachi Virtual Storage Platform G400, G600 Hardware Reference Guide...
  • Page 100: Iscsi Standards

    Path failover HDLM Supports Microsoft MPIO (Multi Path I/O) Link 10 Gbps SFP+ Transfer speed 10 Gbps Connector type Cable Optical OM3, OM2 MMF cable iSCSI standards and specifications Hitachi Virtual Storage Platform G400, G600 Hardware Reference Guide...
  • Page 101 Changeable among 1 to 65,535. Observe the following if changing values: • The setting of the corresponding host should also be changed to log in the new port number. iSCSI standards and specifications Hitachi Virtual Storage Platform G400, G600 Hardware Reference Guide...
  • Page 102 Qualified Name. The iqn consists of a type identifier, "iqn," a date of domain acquisition, a domain name, and a character string given by the individual who acquired the domain. Example: iqn.1994-04.jp.co.hitachi:rsd.d7m.t.10020.1b000.tar iSCSI standards and specifications Hitachi Virtual Storage Platform G400, G600 Hardware Reference Guide...
  • Page 103 Item Specification Comments eui: 64-bit Extended Unique Identifier. The eui consists of a type identifier, "eui," and an ASCII-coded, hexadecimal, EUI-64 identifier. Example: eui.0123456789abcdef iSCSI standards and specifications Hitachi Virtual Storage Platform G400, G600 Hardware Reference Guide...
  • Page 104 Hitachi Virtual Storage Platform G400, G600 Hardware Reference Guide...
  • Page 105: G Replacement Parts

    Replacement parts Part replacement is essential for maintaining the high performance of the system. Replacing system components is covered by the maintenance service contract. Battery unit □ Replacement parts Hitachi Virtual Storage Platform G400, G600 Hardware Reference Guide...
  • Page 106: Battery Unit

    If not, the battery might reach its lifespan earlier than expected and become unusable within three years. When replacing the battery, follow the given procedure for disposing a used battery. Replacement parts Hitachi Virtual Storage Platform G400, G600 Hardware Reference Guide...
  • Page 107: H Regulatory Compliance

    EN61000-3.2:2006+A1 EN61000-3.3:2008 Safety certifications UL and CSA cTUVus USA and Canada 60950-1:2007 EN60950-1:2006+A1 Germany IEC60950-1:2005+A1 All CB countries IEC60950-1:2005+A1 S-Mark Argentina TP TC 004/2011 Russia CNS 14336-1 BSMI Taiwan Regulatory compliance Hitachi Virtual Storage Platform G400, G600 Hardware Reference Guide...
  • Page 108 Product marking or Standard Specification Country regulation logo EN60950-1:2006+A1 Radio interference VCCI V-3/2013.04 VCCI Japan voluntary control Regulatory compliance Hitachi Virtual Storage Platform G400, G600 Hardware Reference Guide...
  • Page 109: Index

    16-Gbps Fibre Channel board 35, 37 chassis 55 32-Gbps Fibre Channel board 35 compliance 107 8-Gbps Fibre Channel board 35 configuration 19 front panel bezels configurations 23 CBLM controller 28 controller 27 Index Hitachi Virtual Storage Platform G400, G600 Hardware Reference Guide...
  • Page 110 70 environmental 94 mounted drive trays 24 hardware 64 iSCSI 100 mechanical 84 RAID 76 storage system 69 network 33 standards 99 number of mounted drive trays 24 Index Hitachi Virtual Storage Platform G400, G600 Hardware Reference Guide...
  • Page 111 79 storing the storage system 66 supported configurations 23 SVP 61 hardware specifications 64 Unified 19 Virtual Storage Platform G400, G600 27 VSP G400 19 without front panel bezel 29 Index Hitachi Virtual Storage Platform G400, G600 Hardware Reference Guide...
  • Page 112 Index Hitachi Virtual Storage Platform G400, G600 Hardware Reference Guide...
  • Page 113 Hitachi Virtual Storage Platform G400, G600 Hardware Reference Guide...
  • Page 114 Hitachi Data Systems Corporate Headquarters 2845 Lafayette Street Santa Clara, California 95050-2639 U.S.A. www.hds.com Regional Contact Information Americas +1 408 970 1000 info@hds.com Europe, Middle East, and Africa +44 (0) 1753 618000 info.emea@hds.com Asia Pacific +852 3189 7900 hds.marketing.apac@hds.com Contact Us www.hds.com/en-us/contact.html...

This manual is also suitable for:

Virtual storage platform g600

Table of Contents