Power LED turned off

Procedure
1.
2.
3.
4.
5.

Ready LED does not go on or Ready LED went on and then off

Procedure
1.
2.
3.
4.
5.
6.
7.

Alarm LED is on

Procedure
1.
390
Is AC power being supplied?
• Yes: Check the power cables are connected properly and turn off the
main switch.
• No: Supply AC power to the storage system and restart the storage
system.
Wait more than a minute and then set the main switch to on.
Is the Power LED on at the controller?
• Yes: Go to step 5.
• No: Set the main switch to off.
Contact your administrator. Go to step 6.
Is the Ready LED on at the controller?
• Yes: Use the equipment in its current operational state, even if the
green Ready LED blinks fast.
• No: Use the following corrective action. See
or Ready LED went on and then off on page
Is the controller Power LED on?
• Yes: Go to step 2.
• No: Go to step 4 in POWER LED does not go on.
Is the ALARM LED on at the controller?
• Yes: See ALARM LED is on.
• No: Go to step 3.
Turn off the main switch.
Wait more than one minute, and then set the main switch to on.
Is the Ready LED on at the controller?
• Yes: Continue to use the equipment. If the green Ready LED blinks
fast, the storage system is operational. Go to step 8.
• No: Go to step 8.
Set the main switch to off.
Contact your system administrator.
Identify which component failed (see
Troubleshooting the storage system
Service Guide for VSP Gx00 and VSP Fx00 Models
Ready LED does not go on
390.
Checking SIM alerts on page
381).