Description Of The Rs232/485 Interface X6C; Connection Of The Rs232 Interface; Connection Of The Rs485 Interface; Table 16: Description Of The Rs232/485 Interface X6C - KEB COMBIVERT F5 Instructions For Use Manual

Frequency converters
Hide thumbs Also See for COMBIVERT F5:
Table of Contents

Advertisement

OPERATION OF THE CONTROL
Required accessories:
Adapter RJ45/DSub-9
00F50C0-0020

8.3.2 Description of the RS232/485 interface X6C

X6C
5 4 3 2 1
5
4
3
2
1
9
8
7
6
9 8 7 6
Table 16:
Description of the RS232/485 interface X6C

8.3.3 Connection of the RS232 interface

A RS232 cable is required to connect the interface operator with a PC.
Serial cable to connect the operator with a PC
6
9

8.3.4 Connection of the RS485 interface

ATTENTION
54
5
9
6
C0F50C0-0020
6
9
1
PIN
RS485
1
-
2
-
3
-
4
A'
5
B'
6
-
7
C/C'
8
A
9
B
0058025-001D
1
5
The following instructions must be observed to prevent malfunctions at
the RS485 interface:
Use CAT 5 cable (in pairs, twisted and screened cable)
Ground to one side (prior to the lower interference side)
Attach terminating resistors of 120 Ω to both ends of the bus
If CAT 7 cable is used (by way of derogation from our recommendation) lay the
interior shield each to the transmitter.
If malfunctions still occur, it is possible to use a biasing. However, this shall be
done only once at the bus (preferably at the master).
Converter HSP5/RS232
00F50C0-0010
1
5
Signal
Meaning
-
reserved
TxD
transmission signal RS232
RxD
receive signal RS232
RxD-A
receive signal A RS485
RxD-B
receive signal B RS485
VP
supply voltage +5 V
(Imax=50 mA)
DGND
data reference potential
TxD-A
transmission signal A RS485
TxD-B
transmission signal B RS485
5
9
6
1
5
9
6
1

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents