OPERATION OF THE CONTROL

8.3.4.1 Wiring RS485 full duplex

Master
TxD-A
TxD-B
RxD-A
RxD-B
Figure 18:
Wiring RS485 full duplex

8.3.4.2 Wiring RS485 half duplex

Master
RXD/TxD-A
RXD/TxD-B
Figure 19:
Wiring RS485 half duplex

8.3.5 Remote control

A special HSP5 operator is available for remote control of the KEB COMBIVERT F5.
Hereby the operator is mounted separate from the drive converter e.g. into the control
cabinet door.
Operator
F5 HSP5 / 485 connection DSUB-15
F5 HSP5 / 485 connection screw terminal
xxx
The last three digits of the material number determine the cable length in dm.

8.3.6 Further operators

Additionally to the described operators, the KEB COMBIVERT can be equipped with
other operators for special applications (PROFIBUS, INTERBUS, SERCOS, CAN). Fur-
ther information can be found in the internet, see www.keb.de.
COMBIVERT
5 4 3 2 1
9 8 7 6
4 5
R
R
COMBIVERT
4
R
8 9
4
5 4 3 2 1
9 8 7 6
8
5
9
Material number
00F5060-9000
00F5060-9001
COMBIVERT
5 4 3 2 1
9 8 7 6
5
8
9
R
R
COMBIVERT
5 4 3 2 1
9 8 7 6
4
8
5
9
R
Suitable cable
00F50C0-2xxx
00F50C0-3xxx