7. If you are instructed to return the internal-cable-management arm, follow all

Replacing the internal-cable-management arm

To install the replacement internal-cable-management arm, complete the following
steps:
1. Insert the bottom tab of the internal-cable-management arm into the lower pivot
2. Rotate the top of the arm toward the front of the server, insert it into the top
3. Route the SAS signal cable or cables through the internal-cable-management
4. Install the bezel and front cover (tower model only) (see "Replacing the top
5. Connect the cables and power cords (see "Connecting the cables" on page 116
6. Turn on all attached devices and the server.

Microprocessor tray and microprocessor

The following notes describe information that you must consider when replacing a
microprocessor.
v When the microprocessor tray is replaced, the BMC MAC address changes to a
v The voltage regulators for microprocessors 1 and 2 are integrated on the
v When installing additional microprocessors, populate the microprocessor
v When installing the microprocessor tray, ensure that the air baffle lies flat and
v A dual-core upgrade option is available to enable the server to support dual-core
packaging instructions, and use any packaging materials for shipping that are
supplied to you.
point.
pivot point, and install the retention clip.
arm.
cover, bezel, and front cover" on page 119).
for cabling instructions).
default value.
microprocessor board; the VRMs for microprocessors 3 and 4 come with the
microprocessor options and must be installed on the microprocessor board.
connectors in numeric order, starting with connector 2.
within the grooves on top of the microprocessor heat sinks and microprocessor
baffles and that the air baffle remains in place while you close the
microprocessor tray. You might find it helpful to hold the air baffle in place with
your thumbs while closing the microprocessor tray.
microprocessors.
Important: The following minimum code levels must be installed for the server
to support the dual-core upgrade:
Basic input/output system (BIOS) code level ZUJT53A
Remote Supervisor Adapter II (RSA2) firmware level ZUEP37B
Baseboard management controller (BMC) code level Z2BT05D
Complex programmable logic device (CPLD) firmware level HEUD18A
Diagnostic program (Diags) code level ZUYT26A
The server model number will change when you install this upgrade. A new label
comes with the option kit for you to place over the existing label on the server.
The following table lists the kit server model numbers before and after the
dual-core upgrade is installed.