IBM System x3800 Problem Determination And Service Manual page 177

Type 8866
Hide thumbs Also See for System x3800:
Table of Contents

Advertisement

Select Disable to prevent memory gap remapping above 64 GB. Enable is
the default setting. Memory gap remapping above 64 GB occurs when 64
GB of system memory is installed. The memory gap created for use by I/O
devices is reclaimed above 64 GB.
– CPU Options
Select this choice to enable or disable the Hyper-Threading Technology and to
select the clustering technology settings.
– PCI Slot/Device Information
Select this choice to view system resources that are used by installed PCI
devices. PCI devices are usually configured automatically. This information is
saved when you exit. The Save Settings, Restore Settings, and Load
Default Settings choices on the Configuration/Setup Utility main menu do not
save the PCI Slot/Device Information settings.
This selection is only available when a Remote Supervisor II Adapter SlimLine
is installed in the server.
– RSA II Settings
Select this choice to view and change Remote Supervisor Adapter II SlimLine
settings. Select Save Values and Reboot RSA II to save the changes you
have made in the settings and restart the Remote Supervisor Adapter II
SlimLine.
– Baseboard management controller (BMC) settings
Select this choice to view information and to change baseboard management
controller (BMC) settings.
- BMC firmware Ver
This is a nonselectable menu item that displays the BMC firmware version.
- BMC POST Watchdog
Enable or disable the BMC POST watchdog. Disable is the default setting.
- BMC POST Watchdog Timeout
Set the BMC POST watchdog timeout value. 5 minutes is the default
setting.
- System BMC Serial Port Sharing
Enable or disable the system BMC serial port sharing. Enable is the default
setting.
- BMC Serial Port Access Mode
Share or disable the BMC serial port access mode. Shared is the default
setting.
- Reboot system on NMI
If you enable this option, the server automatically restarts 60 seconds after
the service processor issues a nonmaskable interrupt (NMI) to the server. If
you disable this option, the server does not restart. Enable is the default
setting.
- BMC Network Configuration
Select this choice to view the BMC Network Configuration information.
- BMC System Event Log
Select this choice to view the BMC system event log, which contains all
system error and warning messages that have been generated. Use the
arrow keys to move between pages in the log. If an optional IBM Remote
Supervisor Adapter II SlimLine is installed, the full text of the error
messages is displayed; otherwise, the log contains only numeric error
codes. Run the diagnostic program to get more information about error
Chapter 5. Configuration information and instructions
161

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents