Permit Modem - Siemens SINUMERIK 840D sl Operating Manual

Sinumerik 840d sl universal
Hide thumbs Also See for SINUMERIK 840D sl:
Table of Contents

Advertisement

Alarm, error, and system messages
13.8 Remote diagnostics
13.8.2

Permit modem

You can permit remote access to your control via a teleservice adapter IE connected at
X127.
Procedure
13.8.3
Request remote diagnostics
Using the "Request remote diagnostics" softkey, from your control you have the option of
actively requesting remote diagnostics with your machinery construction OEM.
The access via modem must be enabled if the access is to be made via modem.
When requesting remote diagnostics, you obtain a window with the corresponding pre-
assigned data and values of the ping service. If required, you can ask your machine
manufacturer for this data.
Data
IP address
Port
Send duration Duration of the request in minutes
270
Machine manufacturer
Please refer to the machine manufacturer's specifications.
Software option
You need the "MC Information System RCS Host" option to display the
"Permit modem" softkey.
1.
The "Remote diagnostics (RCS)" window is opened.
2.
Press the "Permit modem" softkey.
Access to the control via modem is enabled so that a connection can
be established.
3.
To block access again, press the "Permit modem" softkey again.
Machine manufacturer
Please refer to the machine manufacturer's specifications.
Meaning
IP address of the remote PC
Standard port that is intended for remote diagnostics