8. SCANS
SCAN screen
To display the SCAN screen, push
touch [SCAN].
L To select the VFO mode or Memory mode, push
and touch "VFO/MEMORY," and then on the
VFO/MEMORY screen, touch [VFO] or [MEMORY].
Key
PROG
Starts or cancels the Programmed scan.
MEMO
Starts or cancels the Memory scan.
∂F
Starts or cancels the ∂F scan
While Programmed scanning, touch to switch
to the Fine Programmed scan.
While ∂F scanning, touch to switch to the
FINE
Fine ∂F scan.
L In the Memory mode, this key is displayed
when a ∂F scan is started.
Touch to select the ∂F span between ±5 kHz,
∂F SPAN
±10 kHz, ±20 kHz, ±50 kHz, ±100 kHz, ±500
kHz, and ±1 MHz.
Recalls the frequency that was set
Touch
RECALL
before starting the scan in the VFO
1 second
mode.
SET
Displays the SCAN SET screen.
Selects a Memory channel to set
as a Select Memory channel.
Touch
"1," "2," "3," and "(no icon)"
SELECT
are alternately displayed.
Touch
Displays the SELECT ALL CLEAR
1 second
screen.
Selects the Select scan number for the Select
Memory scan.
SEL No.
Each time you touch [SEL No.], "1," "2,"
"3," and "1,2,3" are alternately displayed.
, and then
MENU
Main band: VFO mode
Main band: Memory mode
QUICK
Action
SCAN SET screen
1. Display the SCAN screen.
» SCAN
MENU
2. Touch [SET].
3. Touch an item to set. (Example: SCAN Speed)
4. Touch an option. (Example: Slow)
5. To close the SCAN SET screen, push
SCAN Speed
Set the desired scan speed to slow or fast.
• Slow: Scan speed is slow.
• Fast: Scan speed is fast.
SCAN Resume
Set the Scan Resume function to ON or OFF.
• OFF: When a signal is detected, cancels the scan.
• ON:
When a signal is detected, scan pauses for
10 seconds, then resumes.
Two seconds after the signal disappears, the
scan resumes.
TIP: How to reset to the default settings
Touching an item or its option for 1 second displays
the Quick menu, and then touch "Default" to reset
to the default setting.
67
.
EXIT
(Default: Fast)
(Default: ON)
Need help?
Do you have a question about the IC-7610 and is the answer not in the manual?
Questions and answers