GE D60 Instruction Manual page 706

Line distance protection system
Hide thumbs Also See for D60:
Table of Contents

Advertisement

FLEXANALOG ITEMS
Address
FlexAnalog name
10406
SRC 2 Ic Harm[2]
A
10407
SRC 2 Ic Harm[3]
10408
SRC 2 Ic Harm[4]
10409
SRC 2 Ic Harm[5]
10410
SRC 2 Ic Harm[6]
10411
SRC 2 Ic Harm[7]
10412
SRC 2 Ic Harm[8]
10413
SRC 2 Ic Harm[9]
10414
SRC 2 Ic Harm[10]
10415
SRC 2 Ic Harm[11]
10416
SRC 2 Ic Harm[12]
10417
SRC 2 Ic Harm[13]
10418
SRC 2 Ic Harm[14]
10419
SRC 2 Ic Harm[15]
10420
SRC 2 Ic Harm[16]
10421
SRC 2 Ic Harm[17]
10422
SRC 2 Ic Harm[18]
10423
SRC 2 Ic Harm[19]
10424
SRC 2 Ic Harm[20]
10425
SRC 2 Ic Harm[21]
10426
SRC 2 Ic Harm[22]
10427
SRC 2 Ic Harm[23]
10428
SRC 2 Ic Harm[24]
10429
SRC 2 Ic Harm[25]
10438
SRC 3 Ia THD
10439
SRC 3 Ia Harm[2]
10440
SRC 3 Ia Harm[3]
10441
SRC 3 Ia Harm[4]
10442
SRC 3 Ia Harm[5]
10443
SRC 3 Ia Harm[6]
10444
SRC 3 Ia Harm[7]
10445
SRC 3 Ia Harm[8]
10446
SRC 3 Ia Harm[9]
10447
SRC 3 Ia Harm[10]
10448
SRC 3 Ia Harm[11]
10449
SRC 3 Ia Harm[12]
10450
SRC 3 Ia Harm[13]
10451
SRC 3 Ia Harm[14]
10452
SRC 3 Ia Harm[15]
10453
SRC 3 Ia Harm[16]
10454
SRC 3 Ia Harm[17]
10455
SRC 3 Ia Harm[18]
10456
SRC 3 Ia Harm[19]
10457
SRC 3 Ia Harm[20]
10458
SRC 3 Ia Harm[21]
10459
SRC 3 Ia Harm[22]
10460
SRC 3 Ia Harm[23]
A-12
Units
Description
%
Source 2 phase C current second harmonic
%
Source 2 phase C current third harmonic
%
Source 2 phase C current fourth harmonic
%
Source 2 phase C current fifth harmonic
%
Source 2 phase C current sixth harmonic
%
Source 2 phase C current seventh harmonic
%
Source 2 phase C current eighth harmonic
%
Source 2 phase C current ninth harmonic
%
Source 2 phase C current tenth harmonic
%
Source 2 phase C current eleventh harmonic
%
Source 2 phase C current twelfth harmonic
%
Source 2 phase C current thirteenth harmonic
%
Source 2 phase C current fourteenth harmonic
%
Source 2 phase C current fifteenth harmonic
%
Source 2 phase C current sixteenth harmonic
%
Source 2 phase C current seventeenth harmonic
%
Source 2 phase C current eighteenth harmonic
%
Source 2 phase C current nineteenth harmonic
%
Source 2 phase C current twentieth harmonic
%
Source 2 phase C current twenty-first harmonic
%
Source 2 phase C current twenty-second harmonic
%
Source 2 phase C current twenty-third harmonic
%
Source 2 phase C current twenty-fourth harmonic
%
Source 2 phase C current twenty-fifth harmonic
%
Source 3 phase A current total harmonic distortion
%
Source 3 phase A current second harmonic
%
Source 3 phase A current third harmonic
%
Source 3 phase A current fourth harmonic
%
Source 3 phase A current fifth harmonic
%
Source 3 phase A current sixth harmonic
%
Source 3 phase A current seventh harmonic
%
Source 3 phase A current eighth harmonic
%
Source 3 phase A current ninth harmonic
%
Source 3 phase A current tenth harmonic
%
Source 3 phase A current eleventh harmonic
%
Source 3 phase A current twelfth harmonic
%
Source 3 phase A current thirteenth harmonic
%
Source 3 phase A current fourteenth harmonic
%
Source 3 phase A current fifteenth harmonic
%
Source 3 phase A current sixteenth harmonic
%
Source 3 phase A current seventeenth harmonic
%
Source 3 phase A current eighteenth harmonic
%
Source 3 phase A current nineteenth harmonic
%
Source 3 phase A current twentieth harmonic
%
Source 3 phase A current twenty-first harmonic
%
Source 3 phase A current twenty-second harmonic
%
Source 3 phase A current twenty-third harmonic
D60 LINE DISTANCE PROTECTION SYSTEM – INSTRUCTION MANUAL
APPENDIX A: FLEXANALOG OPERANDS

Advertisement

Table of Contents
loading

Table of Contents