Install the IEC power cord and apply power.
A green indicator in the lower-right indicates power is present. All charge indicators flash
momentarily at powerup to indicate that the charger is ready for operation.
If you choose to wall mount the charger, follow the instructions packaged with the mounting
bracket kit. Be sure to locate the charger in an area where there is no risk of injury to persons
walking in the vicinity.
6.5.2

Operator Controls

The gang charger does not have operator controls or a power switch.
6.5.3

Charge Indicators

Each battery charge slot is equipped with a tri-coloured LED to indicate the charge status of
the battery. When 7535 G2 batteries are inserted in the charger, the colour and behaviour of
the LEDs associated with the charge wells in use indicate the status of the charge.
Table 6.1 Gang Charger Indicators
LED Behaviour
Off
Solid green
Flashing green
Solid yellow
Flashing yellow
Solid red
Flashing red
182
Psion Teklogix 7535 G2 Hand-Held Computer User Manual
Icon
Charge Status
No battery detected in the slot.
Battery is fully charged.
Battery is charged to 75% capacity.
Charge in progress.
Battery temperature out of charge range between 5° C
to 39° C (41° F to 102° F). This icon indicates that the
charger is waiting to charge. Charging is attempted
every five minutes until the battery is within the appro-
priate temperature range.
Battery rejected (at insertion) or unable to complete
charge on battery
Charging circuit problem. Refer to "Troubleshooting"
on page 183.