Omron CP1L-EL20DR-D Operation Manual page 374

Sysmac cp series cp1l-el/em cpu unit
Table of Contents

Advertisement

Inverter Positioning
Stored analog
output value
CP1L-EL/EM
Automatic
calculations
340
Inverter frequency
command value (Hz)
Auxiliary Area
A23/A33
Converting values in A23/A33 to Hz.
Inverter
frequency
100
command value
Unit: 0.01 Hz
Converted in ladder program
Refer to 9-3 Analog Output Units for operating procedures for the Analog Out-
put Unit.
Calculation Example
Conditions
Inverter's maximum output frequency: 60 Hz
Calculation
The stored analog output value is calculated as follows:
Stored analog
output value
Inverter's max. output frequency (Hz)
6,000
1
Inverter maximum
output frequency (Hz)
Auxiliary Area
A23/A33
100
(Unit: 0.01 Hz)
Auxiliary Area
A23/A33
1
(Unit: 0.01 Hz)
Section 7-3
6,000
Stored analog
Analog output
output value
6,000
1
60