FINS Communications
Response Codes

IP ROUTER TABLE WRITE: 2751

Command Block
Response Block
Parameters
Response code
0000
Normal (echo reply received from the remote node)
1001
Command too large
1002
Command too small
1003
The number of records specified does not match the sent data
length.
110C
The number of records is not between 0 and 32.
The FINS node address is not between 1 and 126
The IP address is 0.
2307
IP address conversion method is set for automatic generation.
Writes the IP router table.
27 51
8 bytes
Command
Number
IP router
code
of records
table records
27 51
Command
Response
code
code
Number of Records (Command)
The number of records to write is specified in hexadecimal between 0000 and
0008 in the command. If this value is set to 0, the IP router table will be
cleared so that no records are registered.
IP Router Table Records (Command)
Specify the IP router table records. The number of records specified must be
provided. The total number of bytes in the IP router table records is calculated
as the number of records × 8 bytes/record. The configuration of the 8 bytes of
data in each record is as shown in the following diagram.
1
IP Network address
(Network ID)
IP Network Address
The network ID from the IP address in hexadecimal. The network ID part cor-
responding to the address class (determined by the leftmost 3 bits) set here,
is enabled.
Router IP Address
The IP address (in hexadecimal) of a router connected to a network specified
with IP addresses.
Section 6-5
Description
8 bytes
IP router
table records
8 bytes
Router IP address
187