Settings for PLS2(887) to Return to Start (D10 to D17)

Setting details
Acceleration rate: 300 Hz/4 ms
Deceleration rate: 200 Hz/4 ms
Target frequency: 50,000 Hz
Number of output pulses: 10,000 × 15 pulses
Starting frequency: 100 Hz

Number of Repeats of Fixed-distance Positioning Operation (D20)

Setting details
Number of repeats of fixed-distance positioning operation
(number of PCBs in stocker)
Section 7-2
Address
Data
D10
012C
D11
00C8
D12
C350
D13
0000
D14
49F0
D15
0002
D16
0000
D17
0000
Address
Data
D20
0015