Omron CP1L-EL20DR-D Operation Manual page 328

Sysmac cp series cp1l-el/em cpu unit
Table of Contents

Advertisement

Pulse Outputs
1,2,3...
Instructions Used
Preparation
294
■ System Configuration
Cutter finished
IN 0.02
Built-in I/O other than pulse outputs are used.
■ Operation
1. The workpiece is set at the starting position using the Jogging Switch Input
(IN 0.00).
2. The workpiece is feed the specified distance (relative) using the Position-
ing Switch Input (IN 0.01).
3. When feeding has been completed, the cutter is activated using the Cutter
Start Output (OUT 100.02).
4. Feeding is started again when the Cutter Finished Input (IN 0.02) turns
ON.
5. The feeding/cutting operation is repeated for the number of times specified
for the counter (C0, 100 times).
6. When the operation has been completed, the Cutting Operation Finished
Output (OUT 100.03). is turned ON.
The feeding operation can be canceled and operation stopped at any point
using the Emergency Switch Input (IN 0.03).
SPED(885)
PLS2(887)
■ PLC Setup
There are no settings that need to be made in the PLC Setup.
■ DM Area Settings
Speed Settings for Jogging (D0 to D3)
Setting details
Target frequency: 1,000 Hz
Target frequency: 0 Hz
Cutter start
OUT 100.02
SYSMAC
CP1L
COM
01
03
05
07
09
11
01
03
05
NC
00
02
04
06
08
10
00
02
04
POWER
RUN
ERR/ALM
INH
LNK/ACT
BKUP
1
2
00
01
02
03
04
06
00
01
ANALOG INPUT
COM(V+)
COM
05
07
COM
02
V1+ V2+ COM
MAC Address:
01234567890A
Pulse output (CW/CCW)
Section 7-2
Jogging switch
IN 0.00
Positioning switch
IN 0.01
Emergency stop switch
IN 0.03
07
09
11
06
08
10
03
04
06
COM
05
07
Cut operation finished
OUT 100.03
Address
Data
D0
03E8
D1
0000
D2
0000
D3
0000

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents