3. INSTALLATION

3-11. Connecting the ground wire

Be sure to connect the ground. If the ground connection is not secure, you run the risk of receiving a serious electric shock,
and problems with correct operation may also occur.
(1) Ground wire from the machine head (Ground mark position)
(2) Ground wire from the operation panel
* The recommended tightening torque for the ground screws is 1.0±0.1 N・m.
NOTE:
Make sure that the ground connections are secure in order to ensure safety.
24
CAUTION
KE-430HX/KE-430HS, BE-438HX/BE-438HS
3874B