10. TABLE OF ERROR CODES
Communication and memory-related errors
Code
Communication error was detected with the main P.C. board when the power was turned on.
E400
Turn off the power, and then check that connector P5 on the motor P.C. board is properly connected.
Communication error was detected with the motor P.C. board when the power was turned on.
E401
Turn off the power, and then check that connector on the main P.C. board and connector P23 on the motor P.C.
board are properly connected.
Communication error was detected between main P.C. board and panel P.C. board.
E410
Turn off the power, and then turn it back on again.
Communication error was detected between main P.C. board and motor P.C. board.
E411
Turn off the power, and then turn it back on again.
No USB memory is inserted.
E420
Press the reset key to clear the error.
Data contents are incorrect and cannot be used, or no data.
E421
Press the reset key to clear the error.
Check that data for this pattern number is present in the USB memory.
Error occurred while reading from USB memory.
E422
Press the reset key to clear the error.
Check the data in the USB memory.
Insufficient space in USB memory.
E424
Press the reset key to clear the error.
Use different USB memory.
Error occurred while reading from USB memory.
Press the reset key to clear the error.
E425
Use the specified type of USB memory.
Check if the USB memory is write-protected and if it has enough free space.
A pattern registered in a program has been erased.
E428
Press the reset key to clear the error.
Re-register the program, or add the pattern.
Flash memory of the main P.C. board is faulty.
E430
Turn off the power and change the main P.C. board.
Data cannot be backed up to the main P.C. board.
E440
Turn off the power and change the main P.C. board.
Model selection has not been loaded from the machine head memory.
E450
Turn off the power and check that connector P5 on the power supply motor P.C. board is properly connected.
Machine head memory is not connected.
E452
Turn off the power, and then check that connector P4 on the main P.C. board is properly connected.
Internal memory is full.
E474
Press the reset key to clear the error.
Clear any unnecessary additional patterns and then secure a free space.