Cabinet design and EMC

13.9 Note on control cabinet cooling

13.9
Note on control cabinet cooling
13.9.1

General information

The cabinet can be cooled, among others, by using:
● Filter fans
● Heat exchangers
● Refrigerators
● external air cooling
The decision in favor of one of these methods will depend on the prevailing ambient
conditions and the cooling power required.
The air routing inside the control cabinet and the cooling clearances specified here, must be
carefully observed. Other components or cables must not be installed/routed in these areas.
CAUTION
If you do not observe the guidelines for installing SINAMICS equipment in the cabinet, this
can reduce the service life of the equipment and result in premature component failure.
You must take into account the following specifications when installing a SINAMICS drive
line-up:
● Ventilation clearance
● Wiring and cabling
● Air guidance, air-conditioner
Table 13- 15 Ventilation clearances above and below the components
Component
S120 Combi 3 axes Power Module
S120 Combi 4 axes Power Module
Motor Modules Booksize Compact
Line filters
Line reactors
Braking Module
Control Supply Module
SMC20
DMC20
Terminal Module TM54F
256
Order number
6SL3111-3VE2x-xxA0
6SL3111-4VE2x-xxA0
6SL3420-xTExx-xAAx
6SL3000-0BE21-6DA1
6SL3100-0EE2x-xAA0
6SL3100-1AE31-0AAx
6SL3100-1DE22-0AAx
6SL3055-0AA00-5EAx
6SL3055-0AA00-6AAx
6SL3055-0AA00-3BAx
Clearance [mm]
80
80
80
100
100
80
80
50
50
50
SINAMICS S120 Combi
Manual, Edition 07/2012, 6SL3097-4AV00-0BP3