Siemens SINAMICS S120 Combi User Manual page 94

Hide thumbs Also See for SINAMICS S120 Combi:
Table of Contents

Advertisement

S120 Combi Power Modules
3.9 Technical data
3 axes Power Modules
Feedrate 2
Output current
Rated current (I
)
n
Base-load current (I
)
H
Intermittent duty current (I
Peak current (I
)
max
Rated power
at 540 V DC link voltage
at 600 V DC link voltage
Pulse frequency feedrate 2
Output voltage
Output for expansion axis
DC link voltage
DC link output current (I
n
Max. electronics output current for
expansion axis
General data
Electronics current consumption at 24 V
DC
without external fan unit
with external fan unit
Total power loss
2)
(including electronics losses)
internal
external
Max. ambient temperature
Without derating
With derating
DC link voltage
DC link capacitance
Overvoltage tripping
Undervoltage tripping
Circuit breaker (UL)
Type designation
Rated current:
Resulting rated
short-circuit current SCCR at 480 V
Fuses (UL)
Type AJT Class J
4)
Rated current
Resulting rated
short-circuit current SCCR
at 480 V
AC
at 600 V
AC
Cooling method
92
6SL3111-
A
ACrms
A
ACrms
) 40%
A
S6
ACrms
A
ACrms
kW
kW
kHz
V
ACrms
V
DC
)
A
DC
A
24Vmax
A
A
W
3)
W
W
°C
°C
V
DC
μF
V
DC
V
DC
A
kA
AC
A
kA
kA
3VE21-6FA0
3VE21-6EA0
5
9
4.3
7.7
6.5
12
10
18
2.4
4.3
2.7
4.8
4
0 - 0.7 x DC link voltage
460 – 720
40
20
1.5
1.5
2.3
2.3
425
537
81
91
344
446
45
45
55
55
460 – 720
1645
1880
820 ± 2 %
380 ± 2 %
3VL2105-2KN30
3VL2105-2KN30
50
50
65
65
AJT 35
AJT 35
35
35
65
65
200
200
External air cooling
Manual, Edition 07/2012, 6SL3097-4AV00-0BP3
3VE22-0HA0
9
7.7
12
18
4.3
4.8
1.5
2.3
634
102
532
45
55
2115
3VL2106-2KN30
60
65
AJT 60
60
65
200
SINAMICS S120 Combi