System overview
1.2 System data
Vibratory load
Long-term storage in the transport packaging
Transport in the transport packaging
Operation
Shock load
Long-term storage in the transport packaging
Transport in the transport packaging
Operation
Climatic environmental conditions
Long-term storage in the transport packaging
Transport in the transport packaging
Operation
Table 1- 3
Certificates
Declarations of Conformity
Approvals
24
Class 1M2 according to EN 60721-3-1
Class 2M3 according to EN 60721-3-2
Test values:
Frequency range: 10 Hz to 58 Hz
With constant deflection of 0.075 mm
Frequency range: 58 Hz to 200 Hz
With constant acceleration of 1 g
Class 1M2 according to EN 60721-3-1
Class 2M3 according to EN 60721-3-2
Test values: 15 g / 11 ms
Class 1K4 according to EN 60721-3-1
Temperature: -25 °C to +55 °C
Class 2K4 according to EN 60721-3-2
Temperature: -40 °C to +70 °C
Class 3K3 according to EN 60721-3-3
Temperature +0°C to +45 °C
Relative humidity: 5% to 95 %
Oil mist, salt mist, ice formation, condensation, dripping water,
spray, splash water, water jets are not permitted
CE (Low Voltage and EMC Directives)
cURus