Meaning Of The Leds On The Motor Module Booksize Compact - Siemens SINAMICS S120 Combi User Manual

Hide thumbs Also See for SINAMICS S120 Combi:
Table of Contents

Advertisement

Motor Modules Booksize Compact as expansion axes

7.5 Meaning of the LEDs on the Motor Module Booksize Compact

7.5
Meaning of the LEDs on the Motor Module Booksize Compact
Table 7- 5
Meaning of the LEDs on the Single Motor Module/Double Motor Module
Status
RDY
DC LINK
OFF
OFF
Green
--
Orange
Red
Orange
Orange
Red
--
Green / Red
--
(0.5 Hz)
Green / Red
--
(2 Hz)
Green/Orange
--
or
Red/Orange
Hazardous DC link voltages may be present at any time regardless of the state of the "DC
LINK" LED.
The warning information on the component must be carefully observed!
128
Electronics power supply is missing or outside
permissible tolerance range.
The component is ready for operation and cyclic DRIVE-
CLiQ communication is taking place.
The component is ready for operation and cyclic DRIVE-
CLiQ communication is taking place.
The DC link voltage is present.
The component is ready for operation and cyclic DRIVE-
CLiQ communication is taking place.
The DC link voltage is too high.
DRIVE-CLiQ communication is being established.
This component has at least one fault.
Note:
The LED is activated regardless of whether the
corresponding messages have been reconfigured.
Firmware is being downloaded.
Firmware download is complete. Wait for POWER ON.
Detection of the components via LED is activated
(p0124).
Note:
Both options depend on the LED state when activated
via p0124 = 1.
DANGER
Description, cause
Remedy
Check the line supply
voltage.
Remedy and acknowledge
fault
Carry out a POWER ON
SINAMICS S120 Combi
Manual, Edition 07/2012, 6SL3097-4AV00-0BP3