Electrical connection

Non-assembled MOTION-CONNECT power cables must be appropriately prepared before
being connected to the S120 Combi.
Note
Special issue for UL applications
For UL applications, only 60/75 °C copper conductors may be used.
Cables without connection cables for the motor holding brake
1. Cut the cable jacket to dimension A from the table below
2. Strip the single cores U, V, W and PE and crimp on end sleeves according to DIN 46228
Cables with connection cables for the motor holding brake
1. Cut the cable jacket to 250
2. Cut the single cores U, V, W and PE to dimension A from the table below, strip and crimp
3. Strip the connection cables for the motor holding brake and screw to the brake connector
Figure 3-17
Stripped lengths for power cables
SINAMICS S120 Combi
Manual, Edition 07/2012, 6SL3097-4AV00-0BP3
on end sleeves according to DIN 46228
mm
± 5
S120 Combi Power Modules
3.8 Electrical connection
87