DC link components
8.1 Braking Module Booksize
8.1.8

Technical data

Table 8- 5
Technical data
6SL3100-1AE31-0AB0
DC link voltage
ON threshold
Electronics power supply
Electronics current consumption (at 24 V DC)
Current carrying capacity
DC link busbar
24 V busbar
Rated power
max.
Continuous braking power
Power loss
1)
Cooling method
Weight
1) For an overview, see the power loss tables in chapter Control cabinet installation
8.1.8.1

Characteristic curves

Duty cycle for braking resistors without a thermostatic switch
Figure 8-5
T [s] time period of braking duty cycle
A [s] load duration
P
[W] rated power (continuous power) of braking resistor
N
P
max
148
V
DC
V
V
DC
A
DC
A
DC
A
DC
kW
kW
W
kg
Duty cycle for braking resistors without a thermostatic switch
[W] peak power of braking resistor (6 x P
510 - 720
770
24 (20,4 - 28,8)
0.5
100
20
100
1.5
20
Natural convection
4.1
)
N
Manual, Edition 07/2012, 6SL3097-4AV00-0BP3