Additional System Components; Terminal Module Tm54F; Description - Siemens SINAMICS S120 Combi User Manual

Hide thumbs Also See for SINAMICS S120 Combi:
Table of Contents

Advertisement

Additional system components

10.1

Terminal Module TM54F

10.1.1

Description

The Terminal Module TM54F is a terminal expansion for snapping on to an EN 60715 DIN
rail. The TM54F offers safe digital inputs and outputs for controlling SINAMICS Safety
Integrated functions.
The TM54F must be directly connected to the PPU of SINUMERIK 828D via DRIVE-CLiQ. In
so doing, the topology rules must be observed.
TM54F features the following interfaces:
Table 10- 1
Type
Fail-safe digital outputs (F-DO)
Fail-safe digital inputs (F-DI)
Sensor
Sensor
Digital inputs to check F_DO for a test stop
1) Sensors: Fail-safe devices to issue commands and sense - for example, emergency stop buttons
2) Dynamization: The sensor power supply is cycled on and off by the TM54F when the forced
The TM54F has 4 fail-safe digital outputs and 10 fail-safe digital inputs. A fail-safe digital
output consists of a 24 V switching output, a ground switching output, and a digital input for
checking the switching state. A fail-safe digital input comprises two digital inputs.
Note
The rated values of the F-DO meet the requirements of EN 61131-2 for digital DC outputs
with 0.5 A rated current.
The operating ranges of the F-DI meet the requirements of EN 61131-2 for Type 1 digital
inputs.
Note
Please note that the F-DIs must take the form of shielded cables if they are > 30 m in length.
SINAMICS S120 Combi
Manual, Edition 07/2012, 6SL3097-4AV00-0BP3
Interface overview of the TM54F
power supplies, dynamization supported
1)
power supply, no dynamization
1)
and safety locks, position switches and light arrays/light curtains.
checking procedure is active for the sensors, cable routing, and the evaluation electronics.
2)
10
Number
4
10
2
1
4
173

Advertisement

Table of Contents
loading

Table of Contents