Encoder System Interface - Siemens SINAMICS S120 Combi User Manual

Hide thumbs Also See for SINAMICS S120 Combi:
Table of Contents

Advertisement

Encoder system connection
11.3 Sensor Module External SME25
11.3.2.4

Encoder system interface

Table 11- 10 Encoder system interface SME25
Blanking plate for encoder system interface: Pöppelmann GmbH & Co. KG, Lohne,
Order No.: GPN 300 F211
connector kits, 17-pin, Order No.: 6FX2003-0SA17
NOTICE
The KTY temperature sensor must be connected with the correct polarity.
Risk of electric shock!
Only temperature sensors that meet the safety isolation specifications contained in
EN 61800-5-1 may be connected to terminals "+Temp" and "-Temp".
If these instructions are not complied with, there is a risk of electric shock!
224
Pin
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
DANGER
Signal name
P5
Reserved, do not use
Reserved, do not use
M
+Temp
-Temp
P5
Clock
Clock*
M
Enclosure potential
B
B*
Data
A
A*
Data*
Technical specifications
Encoder power supply
Ground for encoder power supply
Temperature sensor connection
KTY84-1C130 or PTC
Encoder power supply
Clock, EnDat interface,
SSI clock
1)
Inverse clock, EnDat interface,
Inverse SSI clock
1)
Ground for encoder power supply
Incremental signal B
Inverse incremental signal B
Data, EnDat interface,
SSI data
1)
Incremental signal A
Inverse incremental signal A
Inverse data EnDat interface,
Inverse SSI data
1)
SINAMICS S120 Combi
Manual, Edition 07/2012, 6SL3097-4AV00-0BP3

Advertisement

Table of Contents
loading

Table of Contents