X520 Sensor Power Supply; X521 Fail-Safe Digital Inputs + Power Supply With Forced Dormant Error Detection - Siemens SINAMICS S120 Combi User Manual

Hide thumbs Also See for SINAMICS S120 Combi:
Table of Contents

Advertisement

Additional system components
10.1 Terminal Module TM54F
10.1.3.4

X520 sensor power supply

Table 10- 4
X520 sensor power supply
Terminal
1
2
Without forced dormant error detection
10.1.3.5

X521 fail-safe digital inputs + power supply with forced dormant error detection

Table 10- 5
Terminal block X521
Terminal
1
2
3
4
5
6
7
8
An F-DI comprises a digital input and a 2nd digital input where, in addition, the cathode of the optocoupler is fed-out.
F-DI 0 = terminals 2, 3 and 6
F-DI 1 = terminals 4, 5 and 7
Max. connectable cross-section: 1.5 mm²
Type: Screw terminal 1 (see "Control cabinet installation and EMC/Connection system")
1) DI: Digital input, F-DI: Fail-safe digital input
2) Pure hardware delay
176
Designation
L3
M1
Designation
1)
L1+
DI 0
F-DI 0
DI 1+
DI 2
F-DI 1
DI 3+
DI 1-
F-DI 0
DI 3-
F-DI 1
M1
Technical specifications
Voltage: +24 V DC
Max. total load current: 500 mA,
Technical specifications
Voltage: +24 V DC
Max. total load current: 500 mA
Voltage: -3 V to +30 V DC
Typical current consumption: 3.2 mA at 24 V
Electrical isolation:
Reference potential, refer to terminals 6, 7, 8
All digital inputs are electrically isolated.
Level (incl. ripple)
High level: 15 V to 30 V
Low level: -3 V to +5 V
Input delay:
2)
For "0" → "1": 30 μs (100 Hz)
For "1" to "0": 60 μs (100 Hz)
Reference potential for DI 1+
Reference potential for DI 3+
Reference potential for DI 0, DI 2, L1+
Manual, Edition 07/2012, 6SL3097-4AV00-0BP3
SINAMICS S120 Combi

Advertisement

Table of Contents
loading

Table of Contents