HCR 102 Reset Mode Summary — Front Panel-Based Resets
Use This
Activation
Mode to...
Toggle stop/start
To stop or start a program:
program
1.
Hold down the Reset button for about 3 seconds,
until the Power LED blinks once.
2.
Release and press the Reset button momentarily
(for <1 second) within 1 second*.
* Nothing happens if the momentary press does not
occur within 1 second.
Reset IP settings
To reset all IP settings:
and port maps
1.
Hold down the Reset button for about 6 seconds
to factory
until the Power LED blinks twice (once at 3 seconds,
defaults without
again at 6 seconds).
affecting user-
2.
Release and press the Reset button momentarily
loaded files
(for <1 second) within 1 second*.
* Nothing happens if the momentary press does not
occur within 1 second.
Start over with
To reset the unit to all factory default settings via front panel:
configuration
1.
Hold down the Reset button for about 9 seconds
and uploading
until the Power LED blinks three times (once at 3
seconds, again at 6 seconds, again at 9 seconds).
2.
Release and press the Reset button momentarily
(for <1 second) within 1 second*.
* Nothing happens if the momentary press does not
occur within 1 second.
NOTE: After performing a Reset All IP Settings or Reset to Factory Defaults reset, set the IP address again
(by using the OSD menu, Toolbelt, or PCS) for use on your network.
Result
The LED flashes 2 times if the program is
starting.
The LED flashes 3 times if the program is
stopping.
NOTE: This mode is available only via
front panel.
Reset All IP Settings mode:
Sets the LAN IP address back to factory
default (192.168.254.250)
Sets the subnet back to factory default
(255.255.255.0)
Sets the default gateway address to the
factory default (0.0.0.0)
Sets domain and host names to factory
default
Sets port mapping back to factory default
Turns DHCP off
Turns events (user-created schedules,
macros) off.
NOTE: This mode is available only via
front panel.
Reset to Factory Defaults mode performs
a complete reset to factory defaults
(except the firmware).
Resets all AV settings.
Does everything Reset All IP Settings
mode does
Removes (clears) all user-loaded files and
configurations from the HCR 102:
Clears driver-port associations (IR,
serial, Ethernet) and port configurations
Removes schedules, settings, macros
Removes the factory default GC
configuration. The basic GC configuration
project can be downloaded from the
Extron website if you want to restore it to
the unit after a reset.
NOTE: This mode is available via front
panel, Toolbelt, and PCS.
The preferred methods for starting this
reset are front panel and Toolbelt.
In PCS this mode is called "Reset All
Settings and Delete Files."
This is also known as an absolute
system reset.