Loading firmware using PCS
1.
Open PCS. The Device Discovery page opens, displaying a list of detected
devices.
2.
In the device list locate the USB connection row for target HCR 102 unit.
3.
Double-click that row to establish a USB connection to the unit.
4.
In PCS, select Update Firmware and then Update Firmware to This
Device from the drop-down Device Menu (see the PCS - HC 404 Module Help file
for details about working with PCS).
An Update Firmware dialog box opens with a notice not to unplug the USB cable
during the firmware update and reboot and asking whether to continue.
5.
Click Continue to proceed with the firmware update. The Update Firmware to
this Device dialog box opens.
6.
Click Open Firmware File.... The Firmware Files window opens.
7.
Browse to the folder where the firmware file is located and select the firmware file,
which has an .eff extension.
8.
Click Open. The Firmware Files window closes, returning to the Update
Firmware to this Device dialog box, which lists the selected firmware file name.
9.
Click Update. The firmware update proceeds and the dialog box displays progress
messages. When the firmware has been uploaded, the unit reboots, disconnecting
from PCS. PCS closes the device-specific page, returning to the Device Discovery
page and displaying a dialog box that notes the success of the firmware update and
reminding you to reconnect to the device.
HC 404 System • Firmware Updates