Software- And Osd-Based Resets - Extron electronics HC 404 User Manual

Transmitter and receiver collaboration system
Hide thumbs Also See for HC 404:
Table of Contents

Advertisement

Software- and OSD-Based Resets

HCR 102 Reset Mode Summary — Software- and OSD-Based Resets
Use This
Activation
Mode to...
Reset all
To use PCS to reset the unit to factory default settings while
device settings
retaining user-created configuration files and IP settings:
to factory
1.
Open the Extron Product Configuration Software (PCS).
default values,
2.
Locate and connect to the HCR 102 (see the PCS Help file).
but retain
user-created
3.
Select Reset Device... from the device drop-down menu
configuration
within the device tab for the HCR 102. The Reset Device
files and
dialog box opens.
IP settings.
4.
Select (enable) the Reset Device Settings (Retains
TCP/IP Settings) radio button.
5.
Click the Reset button. The dialog box closes and the unit
begins the reset process.
To use the OSD to reset the unit to factory default settings while
retaining the user-created configuration and IP settings:
1.
Using the on-screen display and front panel buttons, navigate
to the OSD Advanced submenu > Factory Reset (see
Factory Reset (via OSD)
2.
Press and hold the front panel Enter button.
Reset all
To use PCS to reset the unit to factory default settings without
device
affecting IP settings:
settings to
1.
Open the PCS software.
factory default
2.
Locate and connect to the HCR 102 (see the PCS Help file for
values, delete
instructions).
user and
3.
configuration
Select Reset Device... from the device drop-down menu
files, but retain
within the device tab for the HCR 102. The Reset Device
dialog box opens.
IP settings.
4.
Select (enable) the Reset Device Settings and Delete
Files (Retains TCP/IP Settings) radio button.
5.
Click the Reset button. The dialog box closes and the unit
begins the reset process.
Start over with
To reset the unit to factory default settings via Toolbelt software:
configuration
1.
Start Toolbelt (run in Administrator mode). The Toolbelt window
and uploading
opens showing a blank list and no devices.
2.
Click the Start Discovery button (located top left) to enable
device discovery. The button changes to Stop Discovery
and the software searches for all available IP Link Pro devices
(including the HCR 102) and associated TouchLink touchpanels
on the network, and displays them in the device list.
3.
Scroll through the device list and click on the IP Address link
or the Manage link in the row for the desired HCR 102 to connect
to the unit and open controls in the right side of the window.
4.
Click the System Utilities tab.
5.
In the System Commands section, click the Reset button. A
confirmation dialog box opens.
6.
Click OK. The dialog box closes, the reset process begins.
To reset the unit to factory default settings via PCS software:
1.
Open the Extron Product Configuration Software (PCS).
2.
Locate and connect to the HCR 102 (see the PCS Help file).
3.
Select Reset Device... from the device drop-down menu
within the device tab for the HCR 102. The Reset Device
dialog box opens.
4.
Select (enable) the Reset All Settings and Delete
Files radio button.
5.
Click the Reset button. The dialog box closes, the unit begins
the reset process. LAN connection to PCS is lost.
on
page 39).
Result
This mode performs a reset to factory
defaults (except IP-related settings, user-
created configurations, and firmware).
Resets all AV settings.
NOTES:
This does not affect IP address, subnet
mask, gateway address, unit name,
DHCP, and related settings.
This mode is available via PCS and
OSD. In PCS this mode is called
"Reset Device Settings (Retains TCP/IP
Settings)."
Reset to Factory Defaults Except IP mode
performs a reset to factory defaults (except
the IP-related settings and firmware).
Resets all AV settings.
Removes all AV-related user-loaded files
and configurations (such as EDID settings
and backup files) from the HCR 102.
Removes the factory default GC configuration.
The basic GC configuration project can be
downloaded from the Extron website if you
want to restore it to the unit after a reset.
NOTES:
This does not affect IP address, subnet
mask, gateway address, unit name,
DHCP, and related settings.
This mode is available only via PCS.
Reset to Factory Defaults mode performs
a complete reset to factory defaults
(except the firmware).
Resets all AV settings.
Does everything Reset All IP Settings mode
does
Removes (clears) all user-loaded files and
configurations from the HCR 102:
Clears driver-port associations (IR, serial,
Ethernet) and port configurations
Removes schedules, settings, macros
Removes the factory default GC
configuration. The basic GC configuration
project can be downloaded from the Extron
website if you want to restore it to the unit
after a reset.
NOTE: This mode is available via front
panel, Toolbelt, and PCS.
The preferred methods for starting this
reset are front panel and Toolbelt.
In PCS this mode is called "Reset All
Settings and Delete Files."
This is also known as an absolute
system reset.
HC 404 System • Operation
44

Advertisement

Table of Contents
loading

Table of Contents